OEM Transmitter DMS HART

OEM Transmitter Strain Gauge HART

type: MASG-E | ID: ▒

technical features

  • Input: 1 strain gauge bridge, 4-wire
  • Bridge resistance: minimal 300 Ohm
  • Sensititivy: 1...4 mV/V
  • Output: 4...20 mA HART (2-wire)
  • Resolution: 16 bit
  • Strain gauge supply: 1 VDC
  • Gross error: 0,3% of range

OEM Tranmitter DMS HART

OEM Transmitter Strain Gauge HART

type: MASG-R | ID: ▒

technical features

  • Input: 1 strain gauge bridge, 4-wire
  • Bridge resistance: minimal 300 Ohm
  • Sensititivy: 1...4 mV/V
  • Output: 4...20 mA HART (2-wire)
  • Resolution: 16 bit
  • Strain gauge supply: 1 VDC
  • Gross error: 0,3% of range

OEM Transmitter Temperatur HART

OEM Transmitter Temperature HART

type: MART-E | ID: ▒

technical features

  • Input: multiple, see data sheet
  • Measurement rate: 100 measurements/s
  • Material PCB: FR4, PBT (electronics fully potted)
  • Output: 4...20 mA HART (2-wire)
  • Resolution: 16 bit
  • Switch-on delay: <5 s
  • Gross error: 0,3% of range

OEM Transmitter Temperatur HART

OEM Transmitter Temperature HART

type: MART-R | ID: ▒

technical features

  • Input: multiple, see data sheet
  • Measurement rate: 100 measurements/s
  • Material PCB: FR4, PBT (electronics fully potted)
  • Output: 4...20 mA HART (2-wire)
  • Resolution: 16 bit
  • Switch-on delay: <5 s
  • Gross error: 0,3% of range

Turbitity Sensor MECS HART

Turbitity Sensor HART

type: MECS | ID: NQ

technical features

  • Input: Infrared sensor 850 nm
  • Output: 4...20 mA current loop HART (2-wire)
  • Voltage supply: 24...30 VDC
  • Measurement range: 0...10 kNTU
  • Process connection: FT-flange
  • Electrical connection: M12x1, 8-pole
  • Ambient temperature: -40...+75 °C (operation)
  • Accuracy: 0,3% of range
  • Material: 1.4571 / 1.4404 / sapphire crystal
  • Protection class: at least IP65
  • Measurement rate: 10 measurements per second

Universal transmitter

universal transmitter

Typ: MH-1U | ID: ▒

technical features

  • measuring input: direct voltage, direct current, Pt100(0), thermocouple, frequency,
    rotational speed, counter
  • display: red display of -199…999 digits
  • digit height approx. 7mm
  • min/max value recording
  • 9 adjustable supporting points
  • display flashing at threshold value exceedance / threshold value undercut
  • Tara function
  • programming interlock via access code
  • pluggable screw-terminal
  • optional: analog output 0-10 VDC, 0/4-20 mA switchable
  • optional: interfaces RS232 / RS485 / Bluetooth
  • optional: sensor supply incl. digital input
  • optional: 2 relay outputs / 2 PhotoMos-outputs / 2 relay outputs & 2 PhotoMos-outputs
  • optional: Bluetooth interface
  • optional: data logger
  • accessories: PC-based configuration kit PM-TOOL with CD & USB adapter

Digital temperature transmitter

Digital temperature transmitter

type: DTT | ID: DY

technical features

  • Input: 1x thermocouple type K (standard)
  • Output: 4...20 mA current loop 2-wire
  • Supply: 10...35 VDC
  • Temperature range: -40...+85 °C
  • Material casing: Plastics, PBT, glas-fiber-reinforced
  • Electrical connection: Solid wire, stranded wire with wire end ferrule
  • Protection class: IP00 / IP20
  • Ex certificates: ATEX, IECEx (option)
  • Cert. (on request): EAC (EMC), Uzstandard

Digital temperature transmitter

Digital temperature transmitter

type: DTW | ID: DX

technical features

  • Input RTD Pt100:1x Pt100, 2-, 3-, 4-wire
  • Input RTD Pt1000: 1x Pt1000, 2-, 3-, 4-wire
  • Input Potentiometer: Reed-chains, 3-wire
  • Output: 4 mA...20 mAcurrent loop 2-wire
  • Power supply: 8...35 VDC
  • Temperature range: -40...+85 °C
  • Casing material: Plastic, plastic PBT , glass fibre reinforced
  • Electrical connection: Solid wire, cord with end splice
  • Protection category: I P00 / I P20

Universal + programmable process controller

Universal + programmable process controller

type: UPPC | ID: ▒

technical features

  • Application: Universal programmable process controller for the control, regulation and visualization of processes up to evalution
  • Supply voltage: 100...240 V AC/24 V DC
  • Sensor supply: 18 VDC / 45 mA
  • Power consumption:
    max. 350 mA (24 V DC)
  • CPU:Cortex A8, 600 MHz … 1 GHz
  • Interfaces: USB-ports
    Back: 1 × USB 2.0 Host (Type A)
    Front: 1 × Mini-USB 2.0 Device (Type B), galvanically isolated
  • Slots: 1 × for communication card; 2 × for I/O-cards
  • Relay: 4 potential-free relay outputs, changeover contacts (230 V AC / 5A; 24 V DC / 5A)
  • Memory:  internal mass memory (4 GByte); Micro SD-Karte;     DDR2 (64 MByte); Flash (128 MByte); MRAM (128 kByte)
  • Real-time clock power failure-buffered
  • Display / Controls: TFT with backlight, 320×240 pixel QVGA, resistive touch screen; 3.5“;         4 freely assignable keys;
    2 programmable LEDs for status indications
  • Housing: witch panel mounting housing
    Dimensions (W×H×D) 98 × 98 × 115 mm (without connectors)
    98 × 98 × 130 mm (with connectors)
  • Protection type: IP 65 on the front, IP 20 rest of housing

Safety control unit

Safety control unit SIL3|PLe 

type: SCU-DR | ID: ▒

technical features

  • Compact-type Safe PLC suitable up to PL e (EN13849) or SIL3 (EN61508)
  • Safe digital inputs: 14 (inclusive 10 OSSD compatible)
  • Safe analog inputs: 2 (4 standard)
  • Safe relay outputs: 3 (6 standard)
  • Standard outputs: 2
  • Pulse outputs (clock): 2 (for cross short circuit detection)
  • Supply: 24 VDC
  • Operation temperature: 50 °C
  • Mounting: Top hat rail
  • Option: Interface modules
  • Protection: IP20
  • Control: Keys for Acknowledge, Start, Reset on front

Transmitter standard signal for DIN rail

Transmitter standard signal for DIN rail

type: SP-DR | ID: ▒

technical features

  • Input current: 0...20 mA - Input Voltage: 0...20 V
  • Input resistance; 0...4000 ohms
  • Output: 4...20 mA, galvanical insulation
  • Supply: 6...32 VDC out of current loop
  • Transmission error: 0,1% FS
  • Configuration: RFID-Programmer
  • Connection: Terminal screws
  • Protection: IP20
  • Dimensions: 18xs90x64 mm
  • Enclosure: Synthetics black

Analog Summing Amplifier 4-Channel

Analog Summing Amplifier 4-Channel

type: DR-AS4K | ID: ▒

technical features

  • Function: Arithmetic mean of input signals
  • Input: 2...4x 4...20 mA
  • Output: 1x 4...20 mA
  • Supply: 24 VDC
  • Current consumption: ca. 50 mA (without input signals)
  • Connection: 4 plug-in terminal stips, 4-pole
  • Temperature range: -10...60 °C (ambient)
  • Protection: IP20
  • Enclosure: DR22,5 made of PA66 GF30

Analog Summing Amplifier 4-Channel

Analog Summing Amplifier 4-Channel

type: DR-AS4K | ID: ▒

technical features

  • Function: Arithmetic mean of input signals
  • Input: 2...4x 4...20 mA
  • Output: 1x 4...20 mA
  • Supply: 24 VDC
  • Current consumption: ca. 50 mA (without input signals)
  • Connection: 4 plug-in terminal stips, 4-pole
  • Temperature range: -10...60 °C (ambient)
  • Protection: IP20
  • Enclosure: DR22,5 made of PA66 GF30

Intelligent sixfold strain gauge summing-up box

Intelligent sixfold strain gauge summing-up box

type: DSV-6E | ID: SE

technical features

  • Input: up to 6 strain gauge full bridges (350Ω)
  • Output: 1 strain gauge summing-up signal
  • Bridge connection: 4- or 6-wire
  • Bridge supply: internally  /  out of amplifier
  • Supply voltage: 12...30 VDC
  • Bridge supply: 10 VDC, 200 mA
  • Cascading: possible
  • Connection: screwed pin and socket, lockable
  • Cable entry: 7 screwed cable glands M16x1,5
  • Protection: IP65
  • Enclosure: impact-resistant plastics, diecast aluminium

Strain gauge amplifier HART

Strain gauge amplifier HART

type: DRMU-S2 - DRSG-S2  | ID: DR series 2

technical features

  • Input: 1 strain gauge full bridge
  • Bridge resistance: 350 Ω minimum
  • Output: 4...20 mA HART current loop
  • Supply: Current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: without
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Strain gauge amplifier HART

Strain gauge amplifier HART

type: DRMU-S4 - DRSG-S4 | ID: DR series 4

technical features

  • Input: 1 strain gauge full bridge
  • Bridge resistance: 350 ohms minimun
  • Output: 4...20 mA HART current loop
  • Supply: 24 VDC, 85...250 VAC, current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: 2x electronically,
    2x relays
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Controller multi-setpoint 32 x 74 mm

Controller multi-setpoint 32 x 74 mm

Type: MATR142 | ID: DC

technical features

  • Version: 2, 3-point or continuous controller
  • Input: Pt100, Pt1000, thermocouples, voltage / current, DI
  • Measuring range: programmable
  • Control mode: PID with auto-tuning
  • Output: Relay, bistable output, RS485
  • Alarm output: Relay contact, programmable alarm function
  • Supply: 24 bis 230 VAC/VDC
  • Material: Polycarbonate UL94V1, self-extinguishing
  • Protection: IP65 front panel (with gasket), IP30 box, IP20 terminals

Double RTD transmitter

Double RTD transmitter

type: DRMU-W | ID: BW

technical features

  • Input: 2x RTD Pt100, 3-wire
  • Output: 2x 4...20 mA (Current loop)
  • Voltage supply: 2x 10...35 VDC
  • Mounting: on top hat rail
  • Temperature ranges: within -50...+400 °C
  • Accuracy: at least 0,5% of range
  • Protection: IP20
  • Enclosure: DR22,5 made of plastic PA66 GF30
  • Connection: plug-in terminal strips

Modular temperature transmitter

Modular temperature transmitter

type: MHTT | ID: HM

technical features

  • Input: RTD / TC / voltage (mV)/ resistance (potentiometer)
  • Output: 4...20 mA current loop, HART protocol
  • Supply: 15...45 VDC out of current loop
  • Accuracy: 0,08...0,12% of range
  • Indication: LCD display (backlighting)
  • Galvanical insulation: input / output
  • Settings: with software via HART-protocol
  • Enclosure: diecast aluminium

Programmable measuring amplifier

Programmable measuring amplifier

type: PMR10 | ID: PM

technical features

  • Input: RTD -100...+850°C, TC -100...+1800°C, resistance and potentiometer 10ohm...10kOhm
  • Configuration: PC with programming software and interface
  • Output 0...20mA, -10...+10V, pulse or relay output
  • Supply voltage 24, 115, 230, 400VAC, or 12...50VDC
  • Galvanic separation

Digital strain gauge amplifier

Digital strain gauge amplifier

type: ADLM-HD | ID: DD

technical features

  • Input: up to 4 strain gauge full bridges
  • Input sensitivity: 0,1...5 mV/V
  • Analog output: 4...20 mA / 0...10 V
  • Voltage supply: 24 VDC +/-30%
  • Resolution: 12 / 14 / 15 / 16 bit
  • Combined error: 0,2% of end scale value
  • Optionally: limit value switch / interface / vibration protection
  • Degree of protection: IP65
  • Adjustment: via RS232 interface

Digital strain gauge and standard signal amplifier

Digital strain gauge and standard signal amplifier

type: ADLM-NS | ID: AD

technical features

  • Input Strain gauge: up to 4 full bridges
  • Input sensitivity: 0,1...5 mV/V
  • Input standard signal: 4...20 mA, 0...10 V
  • Analog output: 4...20 mA / 0...10 V
  • Voltage supply: 24 VDC
  • Resolution: 12 / 14 / 15 / 16 bit
  • Combined error: 0,2% of end scale value
  • Optionally: limit value switch / interface
  • Degree of protection: IP20
  • Adjustment: via RS232 interface

Digital strain gauge amplifier

Digital strain gauge amplifier

type: DR-ADLM | ID: BD

technical features

  • Input Strain gauge: up to 2 full bridges, 0(4)...20 mA, 0...10 V
  • Input sensitivity: 0,1...5 mV/V
  • Analog output: 4...20 mA / 0...10 V
  • Voltage supply: 24 VDC
  • Resolution: 12 / 14 / 15 / 16 bit
  • Combined error: 0,2% of end scale value
  • Optionally: interface
  • Degree of protection: IP20
  • Adjustment: via RS232 or USB interface

Mobile digital strain gauge amplifier

Mobile digital strain gauge amplifier

type: ADLM-HA | ID: DM

technical features

  • Input: 2 strain gauge full bridges
  • Input sensitivity: 0,1...5 mV/V
  • Analog output: 4...20 mA / 0...10 V
  • Voltage supply: accumulator
  • Resolution: 12 / 14 / 15 / 16 bit
  • Combined error: 0,2% of end scale value
  • Degree of protection: IP54
  • Adjustment: via RS232 interface or programming keys

Digital measuring amplifier for strain gauge

Digital measuring amplifier for strain gauge

type: SU-DX | ID: DL

technical features

  • Input sensivity 01 to 5 mV/V
  • Programmable via RS232 interface
  • Analog output 4...20 mA and 0...10 V
  • Supply voltage 24 VDC +/- 30%
  • Combined error 0,2% FS
  • Resolution 12 / 14 / 15 / 16 bit
  • Enclosure plastics
  • Degree of protection IP 67

Sixfold strain gauge summing-up box

Sixfold strain gauge summing-up box

type: DSV-6N | ID: SD

technical features

  • Input: 6 strain gauge full bridges
  • Output: 1 strain gauge summing-up signal
  • Sensors: 4- or 6-wires
  • Bridge supply: out of amplifier or internally
  • Supply: 12...30 VDC VDC (optionally)
  • Cascade circuit possible
  • Connection: screwed pin and socket, lockable
  • Cable entries: 7 pcs M16x1,5

Measuring amplifier strain gauge

Measuring amplifier strain gauge

type: ALM-NS | ID: AN

technical features

  • Input sensitivity (0,1 mV/V up to 4 mV/V) selectable by DIP-switches
  • Connection of max. 4 resistance strain gauge sensors (full bridge, 350 ohms)
  • Change over analog output 0 (4)...+/- 20 mA or 0 (2)...+/-10 V
  • Sensor supply voltage internally continiously adjustable (4...14 V)
  • Optionally 2 adjustable limit value switches (potential free change over contacts)
  • Accuracy +/-0,1% of end of scale value
  • Supply voltage 115/230 VAC

Summin amplifier for resistance strain gauge

Summin amplifier for resistance strain gauge

type: DSV | ID: DV

technical features

  • 4 inputs resistance strain gauge, full bridges
  • Addition of single measure values
  • 1 output for connection to every measuring amplifier with input for resistance strain gauge bridges
  • Cascading of several summing amplifiers is possible
  • External power supply for the bridges can be connected on demand

Digital measuring amplifier for strain gauge

Digital measuring amplifier for strain gauge

type: ADLM-LC | ID: LA

technical features

  • Input sensivity 01 to 5 mV/V
  • Programmable via RS232 interface
  • Analog output 4...20 mA and 0...10 V
  • Supply voltage 24 VDC +/- 30%
  • Combined error 0,2% FS
  • Resolution 12 / 14 / 15 / 16 bit
  • Enclosure stainless steel
  • Degree of protection IP 65

Signal transducer for potentiometer

Signal transducer for potentiometer

type: SU-RX | ID: PU

technical features

  • Input pot 0...400 Ohm up to 0...100 kOhm
  • Analog output 4...20 mA (0...10 V)
  • Supply 24 VDC +/-20%, 12 VDC, 115VAC, 230 VAC
  • Zero drift below 0,2%/10K, gain drift below 0,1%/10K
  • Easy mounting with top hat rail case
  • Degree of protection IP20
  • Adjustment of zero and gain

Programmable converter

Programmable converter

type: PCV10 | ID: PC

technical features

  • Input 15yA...10A (AC/DC), 10mV...1000V (AC) / 1500V (DC)
  • Configuration with programming software and interface
  • Output 0...20mA, -10...+10V, pulse or relay output
  • Supply voltage 24, 115, 230, 400VAC, 12...50VDC
  • Galvanic separation

Limit value switch for standard signals

Limit value switch for standard signals

type: SU-LX | ID: NU

technical features

  • Input 0...10 V, 0(4)...20 mA
  • Relay with change-over contactt
  • Indication of status of relay
  • Switching when above or below limit value
  • Supply 24 VDC +/-20%, optional 115/230 VAC
  • Measuring fault less than 0,5% FS, temperature coefficient 50 ppm/K
  • Easy mounting with top hat rail case
  • Degree of protection IP20
  • Adjustment of limit value and hysteresis

4-input summing amplifier

4-input summing amplifier

type: ASV | ID: SU

technical features

  • 4 inputs 0(4)...20mA, 0...10V, selectable by DIP-switches
  • Adding of input signals
  • Output, 0(4)...20mA, 0...10 V, selectable by DIP-switches
  • Accuracy +/- 0,1% of end of scale value
  • Supply voltage 115/230VAC, optionally 24VAC/DC
  • 2-wire transmitters can be supplied directly by the device

Digital video signal switch

Digital video signal switch

Typ: DVU | ID: VU

technical features

  • 4-channel video signal switch
  • Channel selection "Auto" / "Manual" / "Digital"
  • Switch-over time of the four channels in auto-mode adjustable
  • BNC-jacks for inputs and output
  • Supply: 115/230 VAC, 24 VAC/DC, galvanic separation

Digital Controller REG

Digital controller

type: REG | ID: KR

technical features

  • Input: thermocouple, resistance thermometer
  • Configuration: buttons on the front
  • Digital indicator: for set and actual values
  • Output: 3 relays, voltage-free changeover (250 VAC, 3(5)A
  • Alarm: load interruption, short circuit of the heating element (HB), input for current transformer
  • Control loop monitoring: (LBA alarm, at load interruption or sensor short circuit
  • Option: RS485

Universal digital controller UNIREG

Universal digital controller

Type: UNIREG | ID: UR

technical features

  • Input sensor: thermocouple, resistance thermometer
  • Linear input: 0(10)...50mV, 0(2)...10V, 0(4)...20mA
  • Control outputs: heating/cooling, configurable as relay, logic or analog signal
  • Alarm: up to 5 alarms with eligible functions
  • Alarmfunctions for load breakages
  • Indication: short-circuit, broken sensor, LBA alarm, HB alarm
  • Protection: front IP65

HART-Modem USB

HART-Modem USB

Type: DEV-HM | ID: --

technical features

  • Active operation: current loop is supplied too
  • Passive operation: used in an existing current loop
  • PC interface: virtual serial port
  • Supply: out of USB connection
  • USB specification: 2.0 compatiblel
  • Protection: IP20
  • Galvanical insulation: between USB and HART
  • Case: ABS, 105x66x20 mm

Digital load measuring system

Digital load measuring system

type: DLMHD | ID: LS

technical features

  • TÜV approval for use in systems with AK4
  • µP-device for simple programming
  • 4 resistance strain gauge full-bridge sensors
  • 2 adjustable limit switches, relay output with restraint
  • Configurable analog output, 0...1(10)v or 0(4)...20mA galvanic insulation
  • Interfaces RS232, RS485, Interbus S, LWL, CANbus, Profibus galvanically insulated
  • Tare - function
  • Redundant construction for limit switch and test equipment, monitoring of sensor break and short circuit
  • Accuracy +/- 0,1% of end scale value

Measuring amplifier strain gauge

Measuring amplifier strain gauge

type: ALM-HD2 | ID: AJ

technical features

  • Input sensitivity (0,1 mV/V up to 4 mV/V) selectable by DIP-switches
  • Connection of max. 4 resistance strain gauge sensors (full bridge, 350 ohms)
  • Change over analog output 0 (4)...+/- 20 mA or 0 (2)...+/-10 V
  • Sensor supply voltage internally continiously adjustable (4...14 V)
  • Optionally 2 adjustable limit value switches (potential free change over contacts)
  • Accuracy +/-0,1% of end of scale value
  • Supply voltage 85...265 VAC or 24 VDC

RFID programmable transmitter resistance thermometer

RFID programmable transmitter resistance thermometer

type: TP-RTD | ID: ▒

technical features

  • Input: resistance thermometer, Pt100, Pt1000, Ni100
  • Output: 4...20 mA current loop (2-wire)
  • freely programmable features
  • with setup program LabSoftView for windows
  • max transmission error greater between 0,1% f.s. or 0,2°C
  • Degree of protection IP 20 (IP 54/66, when using terminal head)
  • for use with terminal head form B

RFID programmable transmitter resistance thermometer

RFID programmable transmitter thermocouple

type: TP-TC | ID: ▒

technical features

  • Input: thermocouple
  • Output: 4...20 mA current loop (2-wire)
  • freely programmable features
  • with setup program LabSoftView for windows
  • max transmission error greater between 0,1% f.s. or 0,2°C
  • Degree of protection IP 20 (IP 54/66, when using terminal head)
  • for use with terminal head form B

RFID Programmer

RFID Programmer

type: DEV-RP | ID: ▒

technical features

  • Programming device for setting ISO 15693-compatible target devices
  • for connection to Windows PC with XP and newer
  • Management programm allows three functions:
  • Reading mode: read converter
  • Writing mode: Write parameters in converterEditing mode: Set parameters for the first time
  • Editing mode: Set parameters for the first time

Electronical limit value contacts for MH-Series

Electronical limit value contacts for MH-Series

type: MH-LVE

technical features

  • Input: 4...20 mA HART (current loop)
  • Supply: out of current loop
  • Limit contacts: 2 open collectors (36 VDC, 150 mA)
  • Connection: plug-in terminal strip
  • Accuracy: 0,2% of range, 1 digit
  • Protection: IP20 (PCB)
  • Mounting: plugable with fastening screws
  • Settings: with 3 keys

Controller multi-setpoint / dual input 96 x 48 mm

Controller multi-setpoint / dual input 96 x 48 mm

Type: MATR401 | ID: DC

technical features

  • Version: 2, 3-point or continuous controller
  • Input: Pt100, Pt1000, thermocouples, voltage / current, DI
  • Measuring range: programmable
  • Control mode: PID with auto-tuning
  • Output: Relay, bistable output, 4…20 mA, 0…10 V, RS485
  • Alarm output: Relay contact, programmable alarm function
  • Supply: 24 bis 230 VAC/VDC
  • Material: Polycarbonate UL94V1, self-extinguishing
  • Protection: IP65 front panel (with gasket), IP20 box and terminals

Controller multi-setpoint 48 x 48 mm

Controller multi-setpoint 48 x 48 mm

Type: MATR243 | ID: DC

technical features

  • Version: 2, 3-point or continuous controller
  • Input: Pt100, Pt1000, thermocouples, voltage / current, DI
  • Measuring range: programmable
  • Control mode: PID with auto-tuning
  • Output: Relay, bistable output, 4…20 mA, 0…10 V, RS485
  • Alarm output: Relay contact, programmable alarm function
  • Supply: 24 bis 230 VAC/VDC
  • Material: Polycarbonate UL94V1, self-extinguishing
  • Protection: IP65 front panel (with gasket), IP20 box and terminals

Digital strain gauge amplifier

Strain Gauge Bridge Amplifier SIL3 + PL"e"

type: SMM-HD | ID: ▒

technical features

  • Sensor input: 1x or 2x strain gauge full bridge (350 ohms)
  • Stain gauge sensitivity: up to 4 mV/V
  • Bridge supply: 5 VDC
  • Analog output: 2x 4...20 mA for each strain gauge
  • Voltage supply: 24 VDC +/-10%
  • Accuracy: 5% deviation channel A / channel B
  • Protection: IP20
  • Diagnostic input: Test pulse 24 VDC
  • Enclosure: U-CASE2 (162,2 x 92,2 (101,1) x 60,2 mm)
  • Certificate: SIL 3, Performance Level "e"

DMS - Brücken - Messverstärker SIL3 + PL"e"

Strain Gauge Bridge Amplifier SIL3 + PL"e"

type: SMM-DR | ID: ▒

technical features

  • Sensor input: 1x strain gauge full bridge (350 ohms)
  • Stain gauge sensitivity: up to 4 mV/V
  • Bridge supply: 5 VDC
  • Analog output: 2x 4...20 mA
  • Voltage supply: 24 VDC +/-10%
  • Accuracy: 5% deviation channel A / channel B
  • Protection: IP20
  • Diagnostic input: Test pulse 24 VDC
  • Enclosure: DR22,5 (117,2x22,5x113,6)
  • Certificate: SIL 3, Performance Level "e"

Digital measuring amplifier for strain gauge HART

Digital measuring amplifier for strain gauge HART

type: ADHM-LC | ID: LH

technical features

  • Connection: 1x strain gauge full bridge, 350 ohms
  • Input sensitivity: 1...4 mV/V
  • Configuration: via HART interface
  • Output: 4...20 mA HART
  • Supply: 12...40 VDC out of current loop
  • Electrical connection: pluggable - Combined error: 0,3% of nominal range
  • Resolution: 16 bit
  • Enclosure: stainless steel
  • Protection: IP 65

Transmitter Resistance Thermometer HART

Transmitter Resistance Thermometer HART

type: TH-RTD | ID: ▒

technical features

  • Input RTD: Pt100, Pt1000
  • Output: 4...20 mA current loop
  • Supply: 12...40 VDC out of current loop
  • Accuracy: 0,3% of nominal range
  • Configuration: HART-interface
  • Connection: Terminal screws
  • Protection: IP20
  • Dimensions: d=45x23 mm
  • Enclosure: Synthetics black

Temperature limit value switch HART

Temperature limit value switch HART

type: TGS2 | ID: TG

technical features

  • Input RTD Pt100: 2-wire / -50...500 °C
  • Thermocouple type K: NiCr-Ni / -50..1..200 °C
  • Output: Relay contact (NC or NO)
  • Supply: 24 VDC
  • Accuracy: 0,3% of nominal range
  • Operation temperature: -20...+80 °C
  • Configuration: HART interface, magnet
  • Connection: Terminal screws
  • Protection: IP20
  • Dimensions: Ø45x23 mm
  • Enclosure: Synthetics PA66

Strain gauge amplifier HART

Strain gauge amplifier HART

type: MISG | ID: MJ

technical features

  • Input strain gauge: 1 full bridge, 4-wire
  • Input sensitivity: 1...4 mV/V
  • Output: 4...20 mA HART
  • Voltage supply: 12...40 VDC
  • Resolution: 16 bit
  • Combined error: 0,3% of range
  • Bridge supply: 1 VDC
  • Protection: at least IP65
  • Configuration: Software with HART communication