Tranmitter temperature for DIN rail

Tranmitter temperature for DIN rail

type: TP-DR | ID: ▒

technical features

  • Input RTD: Pt100, Ni100 - Input TC: Type K, S, R, J, B, T, N, E
  • Output: 4...20 mA, galvanical insulation
  • Supply: 6...32 VDC out of current loop
  • Transmission error: 0,1% FS or 0,2 °C
  • Configuration: RFID-Programmer
  • Connection: Terminal screws
  • Protection: IP20
  • Dimensions: 18xs90x64 mm
  • Enclosure: Synthetics black

Converter for resistance HART

Converter for resistance HART

type: DRMU-S2 - DRWI-S2  | ID: DR series 2

technical features

  • Input: 3,3 kΩ
  • Measuring current: 0,15 mA
  • Output: 4...20 mA HART current loop
  • Supply: Current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: without
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Converter for potentiometer HART

Converter for potentiometer HART

type: DRMU-S2 - DRPO-S2  | ID: DR series 2

technical features

  • Input: 3,3 kΩ
  • Measuring current: 0,15 mA
  • Output: 4...20 mA HART current loop
  • Supply: Current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: without
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Standard signal transmitter 0...20 mA HART

Standard signal transmitter 0...20 mA HART

type: DRMU-S4 - DRCU-S4 | ID: DR series 4

technical features

  • Input: 0...20 mA
  • Input resistance: 27 Ω
  • Output: 4...20 mA HART current loop
  • Supply: 24 VDC, 85...250 VAC, current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: 2x electronically,
    2x relays
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Standard signal transmitter 0...10 mA HART

Standard signal transmitter 0...10 V HART

type: DRMU-S4 - DRVO-S4 | ID: DR series 4

technical features

  • Input: 0...10 V
  • Input resistance: 20 kΩ
  • Output: 4...20 mA HART current loop
  • Supply: 24 VDC, 85...250 VAC, current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: 2x electronically,
    2x relays
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Converter for resistance HART

Converter for resistance HART

type: DRMU-S4 - DRWI-S4 | ID: DR series 4

technical features

  • Input: 3,3 kΩ
  • Measuring current: 0,15 mA
  • Output: 4...20 mA HART current loop
  • Supply: 24 VDC, 85...250 VAC, current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: 2x electronically,
    2x relays
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Converter for potentiometer HART

Converter for potentiometer HART

type: DRMU-S4 - DRPO-S4 | ID: DR series 4

technical features

  • Input: 3,3 kΩ
  • Measuring current: 0,15 mA
  • Output: 4...20 mA HART current loop
  • Supply: 24 VDC, 85...250 VAC, current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: 2x electronically,
    2x relays
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

RTD Pt100 amplifier HART

RTD Pt 100 amplifier HART

type: DRMU-S2 - DRRT-S2  | ID: DR series 2

technical features

  • Input: 1 RTD Pt100 (2-,3-,4-wire)
  • Output: 4...20 mA HART current loop
  • Supply: Current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: without
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Standard signal transmitter 0...20 mA HART

Standard signal transmitter 0...20 mA HART

type: DRMU-S2 - DRCU-S2  | ID: DR series 2

technical features

  • Input: 0...20 mA
  • Input resistance: 27 Ω
  • Output: 4...20 mA HART current loop
  • Supply: Current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: without
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

Standard signal transmitter 0...10 mA HART

Standard signal transmitter 0...10 V HART

type: DRMU-S2 - DRVO-S2  | ID: DR series 2

technical features

  • Input: 0...10 V
  • Input resistance: 20 kΩ
  • Output: 4...20 mA HART current loop
  • Supply: Current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: without
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail

RTD Pt100 amplifier HART

RTD Pt100 amplifier HART

type: DRMU-S4 - DRRT-S4 | ID: DR series 4

technical features

  • Input: 1 RTD Pt100 (2-,3-,4-wire)
  • Output: 4...20 mA HART current loop
  • Supply: 24 VDC, 85...250 VAC, current loop
  • Electrical connection: 2...6 plug-in terminal strip
  • Limit vale contacts: 2x electronically,
    2x relays
  • Protection: IP20
  • Accuracy: see data sheet
  • Enclosure: for DIN rail