theater stage technology
View behind the scenery:
On numerous theatre stages of this world the load measurement by Müller Industrie-Elektronik in upper and undermachinery already provides for many years for a maximum in security.
All-round-safety-package: a complete measuring and evaluation system for safe load measurement in tension and compression according to SIL3!
The new Safety-Measuring-Module SMM, that the safety requirements for technical systems safety category 3 (SIL3) according DIN EN 61508 und DIN EN 62061 and the Performance-Levels e, according DIN EN ISO 13849-1 fulfilled, is in combination with a safe evaluation (µC, SPS, PC) a safe and complete measuring and evaluation system for load measurement in tension and compression.
In combination with the new Safety Control Unit SCU-DR the SMM is designed for functional safety according to SIL3 in the upper and lower machinery of stage technological systems.