  • Digital Strain Gauge Amplifier *'*

    type: ADHM-LC | ID: LH

    technical features

    • Connection: 1x strain gauge full bridge, 350 ohms
    • Input sensitivity: 1...4 mV/V
    • Configuration: via interface
    • Output: 4...20 mA
    • Supply: 12...40 VDC out of current loop
    • Electrical connection: pluggable - Combined error: 0,3% of nominal range
    • Resolution: 16 bit
    • Enclosure: stainless steel
    • Protection: IP 65
  • Mobile digital strain gauge amplifier

    type: ADLM-HA | ID: DM

    technical features

    • Input: 2 strain gauge full bridges
    • Input sensitivity: 0,1...5 mV/V
    • Analog output: 4...20 mA / 0...10 V
    • Voltage supply: accumulator
    • Resolution: 12 / 14 / 15 / 16 bit
    • Combined error: 0,2% of end scale value
    • Degree of protection: IP54
    • Adjustment: via RS232 interface or programming keys
  • Digital strain gauge amplifier

    type: ADLM-HD | ID: DD

    technical features

    • Input: up to 4 strain gauge full bridges
    • Input sensitivity: 0,1...5 mV/V
    • Analog output: 4...20 mA / 0...10 V
    • Voltage supply: 24 VDC +/-30%
    • Resolution: 12 / 14 / 15 / 16 bit
    • Combined error: 0,2% of end scale value
    • Optionally: limit value switch / interface / vibration protection
    • Degree of protection: IP65
    • Adjustment: via RS232 interface
  • Digital measuring amplifier for strain gauge

    type: ADLM-LC | ID: LA

    technical features

    • Input sensivity 01 to 5 mV/V
    • Programmable via RS232 interface
    • Analog output 4...20 mA and 0...10 V
    • Supply voltage 24 VDC +/- 30%
    • Combined error 0,2% FS
    • Resolution 12 / 14 / 15 / 16 bit
    • Enclosure stainless steel
    • Degree of protection IP 65
  • Digital strain gauge and standard signal amplifier

    type: ADLM-NS | ID: AD

    technical features

    • Input Strain gauge: up to 4 full bridges
    • Input sensitivity: 0,1...5 mV/V
    • Input standard signal: 4...20 mA, 0...10 V
    • Analog output: 4...20 mA / 0...10 V
    • Voltage supply: 24 VDC
    • Resolution: 12 / 14 / 15 / 16 bit
    • Combined error: 0,2% of end scale value
    • Optionally: limit value switch / interface
    • Degree of protection: IP20
    • Adjustment: via RS232 interface
  • Measuring amplifier strain gauge

    type: ALM-HD2 | ID: AJ

    technical features

    • Input sensitivity (0,1 mV/V up to 4 mV/V) selectable by DIP-switches
    • Connection of max. 4 resistance strain gauge sensors (full bridge, 350 ohms)
    • Change over analog output 0 (4)...+/- 20 mA or 0 (2)...+/-10 V
    • Sensor supply voltage internally continiously adjustable (4...14 V)
    • 2 adjustable limit value switches (potential free change over contacts)
    • Accuracy +/-0,1% of end of scale value
    • Supply voltage 85...265 VAC or 24 VDC
  • Analog Strain Gauge Amplifier

    type: ALM-NS | ID: AN

    technical features

    • Input strain gauge: up to 4 full bridges (350 Ω)
    • Sensitivity strain gauge: 0,1...4 mV/V (by steps)
    • Output: 2...10 V and 4...20 mA, 0...10 V and 0...20 mA
    • Voltage supply: 42 VAC / 115 VAC / 230 VAC / 24 VAC24 VDC
      galvanically isolated
    • Limit value: 2 floating contacts (option)
    • Bridge supply: 4...14 V adjustable
    • Linearity: ± 0,02% of terminal value
    • Mounting: top hat rail
    • Measurement monitoring: sensor break
    • Adjustment limit value: no need to connect strain gauge
  • Digital load measuring system

    type: DLM-HD | ID: LS

    technical features

    • TÜV approval for use in systems with AK4
    • µP-device for simple programming
    • 4 resistance strain gauge full-bridge sensors
    • 2 adjustable limit switches, relay output with restraint
    • Configurable analog output, 0...1(10)v or 0(4)...20mA galvanic insulation
    • Interfaces RS232, RS485, Interbus S, LWL, CANbus, Profibus galvanically insulated
    • Tare - function
    • Redundant construction for limit switch and test equipment, monitoring of sensor break and short circuit
    • Accuracy +/- 0,1% of end scale value
  • Digital strain gauge amplifier

    type: DR-ADLM | ID: BD

    technical features

    • Input Strain gauge: up to 2 full bridges, 0(4)...20 mA, 0...10 V
    • Input sensitivity: 0,1...5 mV/V
    • Analog output: 4...20 mA / 0...10 V
    • Voltage supply: 24 VDC
    • Resolution: 12 / 14 / 15 / 16 bit
    • Combined error: 0,2% of end scale value
    • Optionally: interface
    • Degree of protection: IP20
    • Adjustment: via RS485 or USB interface
  • Strain gauge amplifier *'*

    type: DRMU-S2 - DRSG-S2  | ID: DR series 2

    technical features

    • Input: 1 strain gauge full bridge
    • Bridge resistance: 350 Ω minimum
    • Output: 4...20 mA current loop
    • Supply: Current loop
    • Electrical connection: 2...6 plug-in terminal strip
    • Limit vale contacts: without
    • Protection: IP20
    • Accuracy: see data sheet
    • Enclosure: for DIN rail
  • Strain gauge amplifier *'*

    type: DRMU-S4 - DRSG-S4 | ID: DR series 4

    technical features

    • Input: 1 strain gauge full bridge
    • Bridge resistance: 350 ohms minimun
    • Output: 4...20 mA current loop
    • Supply: 24 VDC, 85...250 VAC, current loop
    • Electrical connection: 2...6 plug-in terminal strip
    • Limit vale contacts: 2x electronically,
      2x relays
    • Protection: IP20
    • Accuracy: see data sheet
    • Enclosure: for DIN rail
  • Summing amplifier for resistance strain gauge

    type: DSV | ID: DV

    technical features

    • 4 inputs resistance strain gauge, full bridges
    • Addition of single measure values
    • 1 output for connection to every measuring amplifier with input for resistance strain gauge bridges
    • Cascading of several summing amplifiers is possible
    • External power supply for the bridges can be connected on demand
  • Sixfold strain gauge summing-up box

    type: DSV-6N | ID: SD

    technical features

    • Input: 6 strain gauge full bridges
    • Output: 1 strain gauge summing-up signal
    • Sensors: 4- or 6-wires
    • Bridge supply: out of amplifier or internally
    • Supply: 12...30 VDC VDC (optionally)
    • Cascade circuit possible
    • Connection: screwed pin and socket, lockable
    • Cable entries: 7 pcs M16x1,5
  • Strain gauge amplifier *'*

    type: MISG | ID: MJ

    technical features

    • Input strain gauge: 1 full bridge, 4-wire
    • Input sensitivity: 1...4 mV/V
    • Output: 4...20 mA
    • Voltage supply: 12...40 VDC
    • Resolution: 16 bit
    • Combined error: 0,3% of range
    • Bridge supply: 1 VDC
    • Protection: at least IP65
    • Configuration: Software
  • Strain gauge amplifier IO-Link

    Typ: MISG-IO | ID: FC

    Technical features

    • Input: 1 strain gauge full bridge
    • Bridge load: minimal 350 Ohm
    • Measurement range: free adjustable in a range of -32000...+32000
    • Output: IO-Link
    • Resolution: 16 bit
    • Strain gauge supply: 3 VDC
    • Gross error: 0,05% of range
    • Electrical connection: several plugs, cable
    • Casing: PBT GF30 black
    • Dimensions: 72x28x35 mm (without electrical connection)
    • Protection class: at least IP65
  • Strain Gauge Bridge Amplifier SIL3 + PL"e"

    type: SMM-DR | ID: ▒

    technical features

    • Sensor input: 1x strain gauge full bridge (350 ohms)
    • Stain gauge sensitivity: up to 4 mV/V
    • Bridge supply: 5 VDC
    • Analog output: 2x 4...20 mA
    • Voltage supply: 24 VDC +/-10%
    • Accuracy: 5% deviation channel A / channel B
    • Protection: IP20
    • Diagnostic input: Test pulse 24 VDC
    • Enclosure: DR22,5 (117,2x22,5x113,6)
    • Certificate: SIL 3, Performance Level "e"
  • Strain Gauge Bridge Amplifier SIL1 + PL"c"

    type: SMM-DR-SIL1 | ID: RA

    technical features

    • Sensor input: 1x strain gauge full bridge (350 ohms)
    • Stain gauge sensitivity: up to 4 mV/V
    • Sensor supply: 1,25…3 VDC
    • Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
    • Voltage supply: 18…35VDC
    • Accuracy: see technical data
    • Protection: IP20
    • Vibration resistance: none
    • Switch output: max. 30 VAC / VDC, at max. 500 mA
    • Enclosure: DR22,5 (117,2x22,5x113,6)
    • Certificate: SIL 1, Performance Level "c"
  • Strain Gauge Bridge Amplifier SIL3 + PL"e"

    type: SMM-HD | ID: ▒

    technical features

    • Sensor input: 1x or 2x strain gauge full bridge (350 ohms)
    • Stain gauge sensitivity: up to 4 mV/V
    • Bridge supply: 5 VDC
    • Analog output: 2x 4...20 mA for each strain gauge
    • Voltage supply: 24 VDC +/-10%
    • Accuracy: 5% deviation channel A / channel B
    • Protection: IP65
    • Diagnostic input: Test pulse 24 VDC
    • Enclosure: U-CASE2 (162,2 x 92,2 (101,1) x 60,2 mm)
    • Certificate: SIL 3, Performance Level "e"
  • Strain Gauge Bridge Amplifier SIL1 + PL"c"

    type: SMM-HD-SIL1 | ID: QX

    technical features

    • Sensor input: 1x strain gauge full bridge (350 O)
    • Strain gauge sensitivity: up to 4 mV/V
    • Sensor supply: 1,25...3 VDC
    • Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
    • Voltage supply: 9…35 VDC
    • Accuracy: see technical data
    • Protection class: IP65
    • Vibration resistance: none
    • Switch output: max. 30 VAC / VDC, at max. 500 mA
    • Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
    • Approvals: SIL1 and Performance level c
  • Strain Gauge Bridge Amplifier SIL1 + PL"c" + IO-Link

    type: SMM-HD-SIL1 | ID: [?]

    technical features

    • […]
    • Sensor input: 1x strain gauge full bridge (350 O)
    • Strain gauge sensitivity: up to 4 mV/V
    • Sensor supply: 1,25...3 VDC
    • Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
    • Voltage supply: 9…35 VDC
    • Accuracy: see technical data
    • Protection class: IP65
    • Vibration resistance: none
    • Switch output: max. 30 VAC / VDC, at max. 500 mA
    • Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
    • Approvals: SIL1 and Performance level c
  • Digital measuring amplifier for strain gauge

    type: SU-DX | ID: DL

    technical features

    • Input sensivity 01 to 5 mV/V
    • Programmable via RS232 interface
    • Analog output 4...20 mA and 0...10 V
    • Supply voltage 24 VDC +/- 30%
    • Combined error 0,2% FS
    • Resolution 12 / 14 / 15 / 16 bit
    • Enclosure plastics
    • Degree of protection IP 67