Select your language

 

Current News

MI-series

  • Differential pressure sensor

    type: MIDS | ID: MD

    technical features

    • Input: 0…10 mbar up to 0…100 mbar
    • Output: current loop 2-wire / voltage output 3-wire
    • Voltage supply: 2-wire current output / 3-wire current-/voltage output
    • Accuracy: see technical data
    • Process connection: 2 x tube connection
    • Medium: clean dry air, dry gases
    • Electrical conncetion: several plugs / cable
    • Temp. range: -20…+80 °C (operation)
    • Housing: UniCase5
    • Protection class: min. IP65
    • Adjustment: factory setting / software (free of charge)
  • Relative Pressure Transmitter *'*

    type: MIPS | ID: MO

    technical features

    • Input: pressure 0...10 mbar bis 0...100 mbar
    • Output: 4...20 mA current loop (2-wire)
    • Voltage supply: out of current loop (12...40 VDC)
    • Accuracy: see technical details
    • Process connection: 1x hose connection
    • Medium: clean dry air, dry gases
    • Electrical connection: several plugs / cable
    • Temperature range: -20...+80 °C (operation)
    • Adjustment: software
    • Material enclosure: PBT GF 30
    • Protection: at least IP65
  • Strain gauge amplifier *'*

    type: MISG | ID: MJ

    technical features

    • Input strain gauge: 1 full bridge, 4-wire
    • Input sensitivity: 1...4 mV/V
    • Output: 4...20 mA
    • Voltage supply: 12...40 VDC
    • Resolution: 16 bit
    • Combined error: 0,3% of range
    • Bridge supply: 1 VDC
    • Protection: at least IP65
    • Configuration: Software
  • Strain gauge amplifier IO-Link

    Typ: MISG-IO | ID: FC

    Technical features

    • Input: 1 strain gauge full bridge
    • Bridge load: minimal 350 Ohm
    • Measurement range: free adjustable in a range of -32000...+32000
    • Output: IO-Link
    • Resolution: 16 bit
    • Strain gauge supply: 3 VDC
    • Gross error: 0,05% of range
    • Electrical connection: several plugs, cable
    • Casing: PBT GF30 black
    • Dimensions: 72x28x35 mm (without electrical connection)
    • Protection class: at least IP65
  • Room temperature sensor *'*

    Type: MITS | ID: MR

    technical features

    • Sensor: RTD Pt100, Pt1000, 2-, 3-, 4-wire
    • Enclosure: inside completely potted
    • Protecting tube: stainless steel 1.4571
    • Range: -30...+60 °C
    • Option: transmitter 4...20 mA
    • Connection: MIL plug, valve plug, M12x1, cable
    • Protection: at least IP65
  • Universal Transmitter 2-channel IO-Link

    Type: MIUT-IO | ID: NO

    Technical features

    • Input channel 1: Strain gauge full bridge
    • Input channel 2: Universal
    • Output: IO-Link
    • Resolution: 16 bit / 24 bit
    • Accuracy: max. 0,05% of nominal range
    • Operating temperature: -20...+85 °C
    • Electrical connection: M12, 5-pole
    • Sensor connection: M12, 8-pole
    • Configuration: Software
    • Material: PBT-GF 30
    • Protection class: IP65