  • Modular Universal Load Cell SIL3 + PL"e"

    type: MULC | ID: CH

    technical features

    • Sensor input: 1x strain gauge full bridge
      (350 ohms)
    • Function load cell: tension load | compression load | tension and compression load
    • Measuring range: 500 kg | 1000 kg | 1500 kg | 3000 kg
    • Analog output: 2x 4...20 mA
    • Power supply: 24 VDC ±10%
    • Accuracy: see data sheet
    • Protection: IP54
    • Vibration protection: electronics completely potted
    • Test input: test pulse 24 VDC, ≤250 Hz
    • Material load cell: stainless steel, alloy steel nickel-plated
    • Certificates: SIL3, Performance Level "e"
  • Pressure transmitter SIL

    type: PT-SIL | ID: UI

    technical features


    • Ranges: 0...0,1 bar up to 0...1000 bar / -1...+24 bar
    • Output: Current / Voltage / Ratiometric
    • Supply: see data sheet
    • Accuracy: 0,5% (0,25%)of span
    • Degree of protection: IP67 (IP65 with valve plug)
    • Casing: 316Ti-steel
    • Process connection: G 1/2, G 1/4, 1/2 NPT, 1/4 NPT
    • Connection: See data sheet
  • Safety control unit SIL3|PLe 

    type: SCU-DR | ID: CR

    technical features

    • Compact-type Safe PLC suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
    • Safe digital inputs: 14 (inclusive 10 OSSD compatible)
    • Safe analog inputs: 2 (4 standard)
    • Safe relay outputs: 3 (6 standard)
    • Standard outputs: 2
    • Pulse outputs (clock): 2 (for cross short circuit detection)
    • Supply: 24 VDC
    • Operation temperature: 50 °C
    • Mounting: Top hat rail
    • Option: Interface modules
    • Protection: IP20
    • Control: Keys for Acknowledge, Start, Reset on front
  • Strain Gauge Bridge Amplifier SIL3 + PL"e"

    type: SMM-DR | ID: ▒

    technical features

    • Sensor input: 1x strain gauge full bridge (350 ohms)
    • Stain gauge sensitivity: up to 4 mV/V
    • Bridge supply: 5 VDC
    • Analog output: 2x 4...20 mA
    • Voltage supply: 24 VDC +/-10%
    • Accuracy: 5% deviation channel A / channel B
    • Protection: IP20
    • Diagnostic input: Test pulse 24 VDC
    • Enclosure: DR22,5 (117,2x22,5x113,6)
    • Certificate: SIL 3, Performance Level "e"
  • Strain Gauge Bridge Amplifier SIL1 + PL"c"

    type: SMM-DR-SIL1 | ID: RA

    technical features

    • Sensor input: 1x strain gauge full bridge (350 ohms)
    • Stain gauge sensitivity: up to 4 mV/V
    • Sensor supply: 1,25…3 VDC
    • Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
    • Voltage supply: 18…35VDC
    • Accuracy: see technical data
    • Protection: IP20
    • Vibration resistance: none
    • Switch output: max. 30 VAC / VDC, at max. 500 mA
    • Enclosure: DR22,5 (117,2x22,5x113,6)
    • Certificate: SIL 1, Performance Level "c"
  • Strain Gauge Bridge Amplifier SIL3 + PL"e"

    type: SMM-HD | ID: ▒

    technical features

    • Sensor input: 1x or 2x strain gauge full bridge (350 ohms)
    • Stain gauge sensitivity: up to 4 mV/V
    • Bridge supply: 5 VDC
    • Analog output: 2x 4...20 mA for each strain gauge
    • Voltage supply: 24 VDC +/-10%
    • Accuracy: 5% deviation channel A / channel B
    • Protection: IP65
    • Diagnostic input: Test pulse 24 VDC
    • Enclosure: U-CASE2 (162,2 x 92,2 (101,1) x 60,2 mm)
    • Certificate: SIL 3, Performance Level "e"
  • Strain Gauge Bridge Amplifier SIL1 + PL"c"

    type: SMM-HD-SIL1 | ID: QX

    technical features

    • Sensor input: 1x strain gauge full bridge (350 O)
    • Strain gauge sensitivity: up to 4 mV/V
    • Sensor supply: 1,25...3 VDC
    • Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
    • Voltage supply: 9…35 VDC
    • Accuracy: see technical data
    • Protection class: IP65
    • Vibration resistance: none
    • Switch output: max. 30 VAC / VDC, at max. 500 mA
    • Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
    • Approvals: SIL1 and Performance level c
  • Strain Gauge Bridge Amplifier SIL1 + PL"c" + IO-Link

    type: SMM-HD-SIL1 | ID: [?]

    technical features

    • […]
    • Sensor input: 1x strain gauge full bridge (350 O)
    • Strain gauge sensitivity: up to 4 mV/V
    • Sensor supply: 1,25...3 VDC
    • Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
    • Voltage supply: 9…35 VDC
    • Accuracy: see technical data
    • Protection class: IP65
    • Vibration resistance: none
    • Switch output: max. 30 VAC / VDC, at max. 500 mA
    • Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
    • Approvals: SIL1 and Performance level c