Strain Gauge Bridge Amplifier SIL1 + PL"c" + IO-Link
type: SMM-HD-SIL1 | ID: [?]
technical features
- […]
- Sensor input: 1x strain gauge full bridge (350 O)
- Strain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25...3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 9…35 VDC
- Accuracy: see technical data
- Protection class: IP65
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
- Approvals: SIL1 and Performance level c
Strain Gauge Bridge Amplifier SIL1 + PL"c"
type: SMM-DR-SIL1 | ID: RA
technical features
- Sensor input: 1x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25…3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 18…35VDC
- Accuracy: see technical data
- Protection: IP20
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Enclosure: DR22,5 (117,2x22,5x113,6)
- Certificate: SIL 1, Performance Level "c"
Modular Universal Load Cell SIL3 + PL"e"
type: MULC | ID: CH
technical features
- Sensor input: 1x strain gauge full bridge
(350 ohms) - Function load cell: tension load | compression load | tension and compression load
- Measuring range: 500 kg | 1000 kg | 1500 kg | 3000 kg
- Analog output: 2x 4...20 mA
- Power supply: 24 VDC ±10%
- Accuracy: see data sheet
- Protection: IP54
- Vibration protection: electronics completely potted
- Test input: test pulse 24 VDC, ≤250 Hz
- Material load cell: stainless steel, alloy steel nickel-plated
- Certificates: SIL3, Performance Level "e"
Pressure transmitter SIL
type: PT-SIL | ID: UI
technical features
- Ranges: 0...0,1 bar up to 0...1000 bar / -1...+24 bar
- Output: Current / Voltage / Ratiometric
- Supply: see data sheet
- Accuracy: 0,5% (0,25%)of span
- Degree of protection: IP67 (IP65 with valve plug)
- Casing: 316Ti-steel
- Process connection: G 1/2, G 1/4, 1/2 NPT, 1/4 NPT
- Connection: See data sheet
Safety control unit SIL3|PLe
type: SCU-DR | ID: CR
technical features
- Compact-type Safe PLC suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Safe digital inputs: 14 (inclusive 10 OSSD compatible)
- Safe analog inputs: 2 (4 standard)
- Safe relay outputs: 3 (6 standard)
- Standard outputs: 2
- Pulse outputs (clock): 2 (for cross short circuit detection)
- Supply: 24 VDC
- Operation temperature: 50 °C
- Mounting: Top hat rail
- Option: Interface modules
- Protection: IP20
- Control: Keys for Acknowledge, Start, Reset on front
Strain Gauge Bridge Amplifier SIL3 + PL"e"
type: SMM-HD | ID: ▒
technical features
- Sensor input: 1x or 2x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Bridge supply: 5 VDC
- Analog output: 2x 4...20 mA for each strain gauge
- Voltage supply: 24 VDC +/-10%
- Accuracy: 5% deviation channel A / channel B
- Protection: IP65
- Diagnostic input: Test pulse 24 VDC
- Enclosure: U-CASE2 (162,2 x 92,2 (101,1) x 60,2 mm)
- Certificate: SIL 3, Performance Level "e"
Strain Gauge Bridge Amplifier SIL3 + PL"e"
type: SMM-DR | ID: ▒
technical features
- Sensor input: 1x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Bridge supply: 5 VDC
- Analog output: 2x 4...20 mA
- Voltage supply: 24 VDC +/-10%
- Accuracy: 5% deviation channel A / channel B
- Protection: IP20
- Diagnostic input: Test pulse 24 VDC
- Enclosure: DR22,5 (117,2x22,5x113,6)
- Certificate: SIL 3, Performance Level "e"
Strain Gauge Bridge Amplifier SIL1 + PL"c"
type: SMM-HD-SIL1 | ID: QX
technical features
- Sensor input: 1x strain gauge full bridge (350 O)
- Strain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25...3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 9…35 VDC
- Accuracy: see technical data
- Protection class: IP65
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
- Approvals: SIL1 and Performance level c