Select your language

 

Current News

calibrators

  • Digital handheld multimeter

    type: DM1-HA

    technical features

    • Input: current AC/DC, voltage AC/DC
    • Input: resistance, capacitance, frequency, temperature
    • Display: 3,75 digits (3999)
    • Accuracy: 0,5...1,5% of range
    • Operation temperature: 0...40 °C
    • Weight: approx. 200 g
    • Supply: 2x 1,5 V (Micro Cell AAA)
    • Contained in delivery: batteries, 1 set measuring cable, probe type K
  • Process calibrator current loop

    type: PC-HA-CL | ID: PK-4

    technical features

    • Input voltage: 28 V
    • Input current / loop current: 20 mA
    • Resolution voltage: 1 mV
    • Resolution current / loop current: 0,001 mA
    • Accuracy voltage: 0,02% of set value / 2 mV
    • Acccuracy current / loop current: 0,02% of set value / 4 µA
    • Output current: 20 mA
    • Output simulation transmitter: -20 mA
    • Output loop supply: 28 V
    • Resolution current: 0,001 mA
    • Resolution simulation transmitter: 0,001 mA
    • Accuracy current: 0,05% of set value / 4 µA
    • Accuracy simulation transmitter: 0,05% of set value / 4 µA
    • Accuracy loop supply: 10%
    • Supply: 9 V battery
    • Contained in delivery: transportation case, 1 set measuring cable
  • Process calibrator RTD

    type: PC-HA-RTD | ID: PK-1

    technical features

    • Output / input resistance: 400 ohms
    • Output / input RTD: PT100 / Cu50
    • Resolution resistance: 0,1 ohms
    • Resolution RTD: 0,1 °C
    • Accuracy resistance: 0,05% of set value / 0,2 ohms
    • Accuracy RTD: 0,05% of set value / 0,6 °C
    • Supply: 9 V battery
    • Contained in delivery: transportation case, 1 set measuring cable
  • Process calibrator thermocouple

    type: PC-HA-TC | ID: PK-2

    technical features

    • Output voltage: 100 mV / 1000 mV
    • Input voltage: 100 mV
    • Output/input thermocouple: Typ R, S, B, E, K, J, T, N
    • Resolution voltage: 0,1 mV / 0,01 mV
    • Resolution thermocouple: 1 °C / 0,1 °C
    • Accuracy voltage: 0,05% of set value / 30µV / 0,3 mV
    • Accuracy thermocouple: 0,05% of set value / 3 °C / 2 °C / 1 °C
    • Supply: 9 V battery
    • Contained in delivery: transportation case, 1 set measuring cable
  • Process calibrator temperature

    type: PC-HA-Temp | ID: PK-3

    technical features

    • Output voltage: 100 mV / 1000 mV
    • Output resistance: 400 ohms
    • Output TC: types R, S, B, E, K, J, T, N
    • Output RTD: Pt100 / Cu50
    • Resolution voltage: 0,1 mV / 0,01 mV
    • Resolution resistance: 0,1 Ohm
    • Resolution TC: 1 °C / 0,1 °C
    • Resolution RTD: 0,1 °C
    • Accuracy voltage: 0,05% of set value / 30µV / 0,3 mV
    • Accuracy resistance: 0,05% of set value / 0,2 Ohm
    • Accuracy TC: 0,05% of set value / 3 °C / 2 °C / 1 °C
    • Accuracy RTD: 0,05% of set value / 0,1 °C
    • Supply: 9 V battery
    • Contained in delivery: transportation case, 1 set measuring cable
  • Process calibrator current voltage

    type: PC-HA-VmA | ID: PK-0

    technical features

    • Output current: 20 mA
    • Output voltage: 10 V
    • Output: simulation transmitter
    • Output: power supply current loop
    • Resolution current: 0,001 mA
    • Resolution voltage: 1 mV
    • Accuracy current: 0,05% of set value/ 4 µA
    • Accuracy voltage: 0,05% of set value / 2 mV
    • Supply: 9 V battery
    • Contained in delivery: transportation case, 1 set measuring cable
  • Process calibrator multifunction

    type: PC-MF | ID: PF

    technical features

    • Output Current: 20 mA
    • Output Voltage: 100 mV, 1V, 10 V
    • Output Resistanc: 400 Ohms, 4 kOhms, 40 kOhms
    • Output TC: Types R, S, K, E, J, T, N, B
    • Output RTD: Pt100, Pt1000, Cu50
    • Output Frequency: 100 Hz, 1 kHz, 10 kHz, 100 kHz
    • Output Pulse sequence: 10...100000 cycles
    • Output Pulse switch interval: 100 Hz, 1 kHz, 10 kHz, 100 kHz
    • Other Outputs: Simulation transmitter, Loop supply
    • Input Current: 50 mA
    • Input Voltage: 50 mV, 500 mV, 5 V, 50 V
    • Input Resistance: 500 Ohms, 5 kOhms
    • Input Frequency: 100 Hz, 1 kHz, 10 kHz
    • Input TC: Types R, S, K, E, J, T, N, B
    • Input RTD: Pt100, Pt1000, Pt200, Pt500, Cu10, Cu50
    • Other Inputs: contact test, Continuity test
    • Basic accuracy: 0,02%
    • Supply: 4x 1,5 V AAA batteries