Digital indicator -

current loop display in robust field enclosure

type: CULO-F | ID: CF

technical features

  • Input 1: 4...20 mA (current loop)
  • Supply 1: out of current loop
  • Input 2: (0)4...20 mA / 0...10 V (external supply)
  • Supply 2: 115/230 VAC / 24 VDC (no galvanical insulation)
  • Limit contacts: 2 open collectors / 2 relays
  • Display range: -999...9999
  • Memory: minimum/maximum
  • Unit: dimension strip (fixed under front foil)
  • Enclosure: ABS/FR / diecast aluminium
  • Protection: IP 66 (enclosure)
  • Measuring fault: ±0,2% of range, ±1 digitInput: 4...20 mA current loop

Digital indicator resistance - digit height 14mm

Digital indicator resistance,
digit height 14mm

type: M1 | 72 x 36

technical features

  • Display: 4 digits (-1999...9999)
  • Color: red (Option: green, orange, blue)
  • Operation: front panel keyboard, IP65
  • Input: 1 k ohms, 10 k ohms, 100 k ohms, 1 M ohms
  • Switching output: 2 relays, 250 VAC / 5 AAC, 30 VDC / 5 ADC
  • Supply: 24 VDC, 230 VAC
  • Other: Linearization, flashing display, tare, software tool

Digital indicator resistance - digit height 14mm

Digital indicator resistance,
digit height 14mm

type: M1 | 96 x 24

technical features

  • Display: 4 digits (-1999...9999)
  • Color: red (Option: green, orange, blue)
  • Operation: front panel keyboard, IP65
  • Input: 1 k ohms, 10 k ohms, 100 k ohms, 1 M ohms
  • Supply: 24 VDC, 230 VAC
  • Other: Linearization, tare, display flashing, software tool

Digital indicator resistance - digit height 14mm

Digital indicator resistance,
digit height 14mm

type: M1 | 96 x 48

technical features

  • Display: 4 digits (-1999...9999)
  • Color: red (Option: green, orange, blue)
  • Operation: front panel keyboard, IP65
  • Input: 1 k ohms, 10 k ohms, 100 k ohms, 1 M ohms
  • Supply: 24 VDC, 230 VAC
  • Other: Linearization, tare, flashing display, software tool

Double RTD transmitter

Double RTD transmitter

type: DRMU-W | ID: BW

technical features

  • Input: 2x RTD Pt100, 3-wire
  • Output: 2x 4...20 mA (Current loop)
  • Voltage supply: 2x 10...35 VDC
  • Mounting: on top hat rail
  • Temperature ranges: within -50...+400 °C
  • Accuracy: at least 0,5% of range
  • Protection: IP20
  • Enclosure: DR22,5 made of plastic PA66 GF30
  • Connection: plug-in terminal strips