HART-Modem USB

HART-Modem USB

Type: DEV-HM | ID: --

technical features

  • Active operation: current loop is supplied too
  • Passive operation: used in an existing current loop
  • PC interface: virtual serial port
  • Supply: out of USB connection
  • USB specification: 2.0 compatiblel
  • Protection: IP20
  • Galvanical insulation: between USB and HART
  • Case: ABS, 105x66x20 mm

M3 - tricolour - DMS - mass pressure - digit height 14 mm

Digital indicator strain gauge / mass pressure
digit height 14 mm

type: M3 tricolour strain gauge / mass pressure | 96 x 48

technical features

  • Display: 5 digits (-19999...99999)
  • Color: red, green, orange switchable
  • Operation: front panel keyboard
  • Input: strain gauge / mass pressure 1...4 mV/V
  • Switching contact: 2 or 4 relays (Option) Contact: 250 VAC / 5 AAC, 30 VDC / 5 ADC Option: 8 PhotoMos outputs
  • Analog output: 1x / 2x: 0/4...20 mA, 0...10 V
  • Interface: RS232, RS422 (galvanically insulated)
  • Sensor supply: 10 VDC / 20...40 mA
  • Supply: 10...40 VDC, 100...240 VAC, 18...30 VAC
  • Digital input
  • Other: Linearization, min/max, tare, software tool

Calorimetric flow sensor for gases

Calorimetric flow sensor for gases

Type: MEFS-K | ID: OU

technical features

  • Input: 0...10 m/s up to 0...30 m/s
  • Output: 4...20 mA
  • Supply: 24 VDC
  • Process connection: several options
  • Elecrical connection: serveral options
  • Temperature range: 0...+60 °C (ambient)
  • Limit value contacts: 2x electronically (NPN/PNP)
  • Protection: at least IP65
  • Adjustment: keys

PM5 - DMS - mass pressure - digit height 14 mm

Digital indicator strain gauge / mass pressure
digit height 14 mm

type: PM5 strain gauge / mass pressure | 96 x 48

technical features

  • Display: 5 digits (-9999...99999)
  • Color: red
  • Operation: front panel keyboard
  • Input: strain gauge / mass pressure 1...6 mV/V
  • Switching contact: Relay (Option)
  • Analog output: 1x 0/4...20 mA, 0...10 V
  • Interface: RS232, RS485
  • Sensor supply: 10 VDC / 50 mA
  • Digital input

Flush pressure transmitter

Flush Pressure Transmitter

Typ: PT-FR | ID: UF

technical features

  • Diaphragm: flush type
  • Range: 0...0,1 bar up to 0...600 bar
  • Output: 4...20 mA/0...20 mA / 0...10 V /
    0...5 V
  • Accuracy: 0,5% of span
    (option: 0,25% of span)
  • Temperature medium: -30...+100 °C / -30...+125 °C / -20...+150 °C
  • Material enclosure: CrNi steel
  • Pressure connection: G1/2 B / G1 B /
    Hygienic G1 B
  • Protection: IP65 up to IP68