Select your language

 

Current News

pressure measurement

  • Bubbling through pressure transducer

    type: ADLM-P | ID: EP

    technical features

    • Measurement: Positive relative pressure (hydrostatic pressure)
    • Range: 0...1000 mbar, 0...50 mbar, 0...100 mbar, 0...200 mbar, 0...350 mbar
    • Output: 0..10V and 4...20mA
    • Accuracy: up to 1% of end scale value
    • Supply voltage: 24 VDC, +/-20%
    • Level measuring in all liquids possible
    • Aggressive and abrasive media are no problem
      Distance of point of bubbling through up to 50 m
  • ship

    Bubbling through pressure transducer with valve

    type: ADLM-PV | ID: EV

    technical features

    • Measurement: Positive relative pressure (hydrostatic pressure)
    • Range: 0...1000 mbar, 0...50 mbar, 0...100 mbar, 0...200 mbar, 0...350 mbar
    • Output: 0..10V and 4...20mA
    • Accuracy: up to 1% of end scale value
    • Supply voltage: 24 VDC, +/-20%
    • Level measuring in all liquids possible
    • Aggressive and abrasive media are no problem
    • Distance of point of bubbling through up to 50 m
  • Pressure transmitter

    type: ATM | ID: PD

    technical features

    • Relative, absolute or overpressure
    • Ranges from 0...0,1bar up to 0...1000bar
    • Output current or voltage
    • Supply voltage 11...33VDC
    • Accuracy 0,1% of end scale value
    • Degree of protection IP65, special types up to IP68
    • Medium contact parts and case of stainless steel (CrNi)
    • Process connection G 1/2 A, G 1/4 A, 1/2 NPT, 1/4 NPT
    • EX-protection intrinsically safe
  • Digital indicator - current loop display

    type: CULO-L | ID: CL

    technical features

    • Mounting: in housings >IP20
    • Input: 4...20 mA current loop
    • Range of indication: programmable -999...9999
    • Voltage across: below 3,2 V
    • Programmind: via 3 keys
    • Unit: digit 4 programmable (°C/°F)
    • Option: II 2G Ex ia IIC T6
    • Option: II 3G Ex nR II T6
    • Protection: front IP 67
    • Housing: DIN BUZ-H head, wall- tube mounting, built-on
  • Modular Differential Pressure Transmitter *'*

    type: MEDS | ID: NJ

    technical features

    • Input: differential pressure (range: 75 mbar to 70 bar)
    • Output: 4...20 mA current loop (12...45 VDC)
    • Accuracy: 0,075%, 0,1% of range (URL, LRL)
    • Setting: with keys and/or software
    • Material adapter: for process adapter M56: Stainless steel 1.4571
    • Material process: for pressurized parts: 1.4435
    • Electr. connection: several options available, see page 5
    • Process connection: 1/4-18 NPT
    • Operating temp.: -20...+70 °C
    • Protection classt: IP65
    • Display: 3 capacitive keys, 4-digits, 180° mirrorable
  • Melt Pressure Sensor *'*

    type: MEMP-T | ID: AC

    technical features


    • Input: 0...50 bar up to 0...1200 bar
    • Output: 4...20 mA, 2-wire / CANopen
    • Supply: by current loop 12...32 VDC
    • Accuracy: <0,5% of terminal value
    • Process connection: 1/2"-20UNF-2A with / without capillary tube
    • Electr. connection: MIL (standard), M12, cable outlet
    • Environmental temp.: -20...+85 °C
    • Medium temperature: -30...+410 °C
    • Setting: Software
    • Material: 1.4571 CrNi stainless steel
    • Protection class: at least IP65 / IP68
  • ship

    Pressure switch standard

    type: MEPL-S | ID: NP

    technical features

    • Input: 0...0,1 up to 0...1000 bar
    • Output: Relay with changeover contact
    • Voltage supply: 24...30 VDC
    • Accuracy sensor: 0,5% of nominal range
    • Process connection: G 1/2" / G 1/4" / 1/2 NTP / 1/4 NPT
    • Electrical connection: M12x1, 8-pole
    • Indication: LED red- Ambient temperature: -30...+80 °C (operation)
    • Adjustment switch point: by magnet / software
    • Material: Stainless steel 1.4571 (contact with medium)
    • Ingress protection: at least IP65
  • Pressure Sensor - Flush *'*

    type: MEPS-F | ID: OZ

    technical features

    • Input: 0...0,1 to 0...600 bar / 0...0,25 to 0...16 bar
    • Output: 4...20 mA current loop (2-wire)
    • Supply: out of current loop (12...40 VDC)
    • Accuracy: see technical data
    • Process connection: G1/2B / G1B flush-mounted / G1 hygienic
    • Electrical connection: several options (page 3)
    • Ambient temperature: -20...+80 °C (operation)
    • Limit value contacts: 2x electronic (NPN, PNP)
    • Setting: Keys / Software
    • Medium temperature: -30...+100 °C
    • Protection: at least IP65
  • Pressure Transmitter Hygiene *'*

    type: MEPS-H | ID: OQ

    technical features

    • Input: 0…160 mbar up to 0...25 bar
    • Output: 4…20 mA current loop (2-wire)
    • Supply: from current loop 12...40 VDC
    • Accuracy: see Technical Data
    • Process connection: flange hygiene version
    • Electrical connection: multiple options
    • Ambient temperature: -20…+80 °C (operation)
    • Limit value contacts: 2x electronic (NPN, PNP)
    • Setting: keys / software
    • Medium temperature: -30…+100 °C
    • Protection class: at least IP65
  • Pressure sensor standard *'*

    type: MEPS-S | ID: OP

    technical features

    • Pressure: relative, absolute
    • Ranges 0...0,1 bar up to 0...1000 bar
    • Potting: electronics completely potted
    • Material: in contact with medium stainless steel 1.4571
    • Process connection: 1/2" / 1/4" / 1/2NPT / 1/4NPT
    • Output: 4...20 mA
    • Limit value contacts: 2 electronically
    • Configuration: with keys/software
    • Connection: M12, Super Seal, Deutsch, Bayonet, valve, cable
    • Protection: at least degree IP65
  • Pressure sensor

    type: MEPS-T | ID: OD

    technical features

    • Input: pressure 0…0,1 up to 0…1000 bar
    • Output: 4…20 mA (2-wire)
    • Voltage supply: out of current loop (12…35 VDC)
    • Accuracy: see technical details
    • Process connection: several options
    • Electrical connection: lateral, Option: upwards
    • Electrical connection: several plugs / cable
    • Temperature range: -20…+80 °C (operation)
    • Adjustment: software (TrComm)
    • Temperature medium: -30…+100 °C
    • Protection: at least IP65 / IP68
  • Pressure sensor Ex

    type: MEPS-TEx | ID: GH

    technical features

    • Input: pressure 0…0,1 up to 0…1000 bar
    • Output: 4…20 mA, 2-wire / 0…10 V, 3-wire
    • Voltage supply: 12…30 VDC
    • Accuracy: see technical details
    • Process connection: several options
    • Electrical connection: lateral, Option: top
    • Electrical connection: several plugs / cable
    • Temperature range: -20…+75 °C, 2-wire / -20…+50 °C, 3-wire
    • Explosion protection: ATEX, IECEx
    • Medium temperature: 0…+100 °C
    • Protection class: at least IP65 / IP68

  • Modular differential pressure transmitter ***

    type: MHDS | ID: HD

    technical features

    • Pressure: differential
    • Ranges from 10 mbar … 100 bar
    • Output: 4...20 mA
    • Supply voltage: current loop, 15...30VDC
    • Accuracy: 0,1%, 0,075%, 0,2% of span
    • Degree of protection: IP65
    • Medium contact parts stainless steel 1.4435
    • Process connection 1/4-18NPT
    • Display with programming keys
    • Turn down up to 100:1
  • Modular pressure transmitter ***

    type: MHPS | ID: HP

    technical features

    • Pressure: relative, absolute
    • Ranges 0...0,1 bar up to 0...1000 bar
    • Output: 4...20 mA
    • Supply voltage: current loop, 15...30VDC
    • Accuracy: 0,25% (0,5%) of span
    • Degree of protection: IP65
    • Medium contact parts: CrNi steel
    • Process connection: 1/2" / 1/4" / 1/2NPT / 1/4NPT / M20x1,5
    • Display with programming keys
    • Turn down up to 100:1
  • Differential pressure sensor

    type: MIDS | ID: MD

    technical features

    • Input: 0…10 mbar up to 0…100 mbar
    • Output: current loop 2-wire / voltage output 3-wire
    • Voltage supply: 2-wire current output / 3-wire current-/voltage output
    • Accuracy: see technical data
    • Process connection: 2 x tube connection
    • Medium: clean dry air, dry gases
    • Electrical conncetion: several plugs / cable
    • Temp. range: -20…+80 °C (operation)
    • Housing: UniCase5
    • Protection class: min. IP65
    • Adjustment: factory setting / software (free of charge)
  • Relative Pressure Transmitter *'*

    type: MIPS | ID: MO

    technical features

    • Input: pressure 0...10 mbar bis 0...100 mbar
    • Output: 4...20 mA current loop (2-wire)
    • Voltage supply: out of current loop (12...40 VDC)
    • Accuracy: see technical details
    • Process connection: 1x hose connection
    • Medium: clean dry air, dry gases
    • Electrical connection: several plugs / cable
    • Temperature range: -20...+80 °C (operation)
    • Adjustment: software
    • Material enclosure: PBT GF 30
    • Protection: at least IP65
  • Modular compact differential pressure transmitter *'*

    type: MKDS | ID: MP

    technical features

    • Pressure: differential
    • Ranges from 75 mbar up to 70 bar
    • Output: 4...20 mA
    • Supply voltage: current loop, 12...30VDC
    • Accuracy: 0,1%, 0,075%, 0,2% of span
    • Degree of protection: IP65
    • Medium contact parts stainless steel 1.4435
    • Process connection 1/4-18NPT
    • Turn down up to 100:1
  • Modular Universal Differential Pressure Sensor

    type: MUDS | ID: JR

    technical features

    • Input: Differential pressure
    • Output: 4…20 mA / 0…10 VDC
    • Voltage supply: 9…35 VDC / 12…35 VDC / 12…24 VAC
    • Accuracy: see technical data
    • Process connection: 2x 1/4" socket connection (VA inserts)
    • Medium: liquids and gases
    • Electrical connection: several plugs / cable
    • Temperature range: -40…+80 °C (operation)
    • Configuration: Software
    • Material casing: PBT GF 30 / 1.4571 / Aluminum (anodized)
    • Protection class: at least IP65
  • Pressure measuring transducer

    type: NDR | ID: DN

    technical features

    • Positive and negative over pressure differential pressure, absolute pressure
    • Measurement range 0...0,1mbar up to 0...1000mbar, Special absolute ranges
    • Output 0..10V, 0(4)...20mA, -5...+5 V, -10...+10 V, 4...20 mA 2-wire
    • Accuracy 1%, 0,5%, 0,2% of end scale value
    • Supply voltage 19...31 VDC, 230 VAC, 115 VAC, 24 VAC
    • LCD digital display 3,5 digit
    • Square root function for output signal
    • Limit contacts
  • Pressure transducer mobile

    type: PS-LC | ID: UL

    technical features

    • Kind of pressure: relative
    • Pressure ranges: 0...10 bar up to 0...1000 bar
    • Output: 4...20 mA, 0...20 mA, 0...10 V, 0...5 V, 1...6 V
    • Material in contact with medium: stainless steel CrNi
    • Accuracy: up to 1% FS
    • Degree of protection: at least IP67
    • Process connection: 1/4", 1/4"NPT, M14x1,5, SAE 04, SAE 06
    • Temperature medium: -40...150 °C
    • Connection: M12, Super Seal, Deutsch, Bayonet, Cable
  • Pressure transmitter economic

    type: PT-AL | ID: UA

    technical features

    • Pressure: relative or absoluta
    • Ranges: 0...1 bar up to 0...600 bar
    • Output: 4...20 mA, 0...10 V, 0...5 V, 1...5 V 0,5...4,5 V, 0,5...4,5 V ratiometric
    • Supply voltage: current loop, 8(14)...30(36)VDC, 5 VDC
    • Accuracy: 0,5% (0,25%)of range
    • Protection: IP65 bzw. IP67
    • Wetted parts: 316L, 13-18-PH
    • Pressure connection: G 1/4A, G 1/4, G1/4 female; 1/4NPT, 1/4NPT female, M20x1,5, R1/4 ISO7, PT1/ 2, 7/16-20 UNF
    • Connection: L-plug (valve), M12x1, cable, L-plug DIN 175-301-803C
  • Flush Pressure Transmitter

    Typ: PT-FR | ID: UF

    technical features

    • Diaphragm: flush type
    • Range: 0...0,1 bar up to 0...600 bar
    • Output: 4...20 mA/0...20 mA / 0...10 V /
      0...5 V
    • Accuracy: 0,5% of span
      (option: 0,25% of span)
    • Temperature medium: -30...+100 °C / -30...+125 °C / -20...+150 °C
    • Material enclosure: CrNi steel
    • Pressure connection: G1/2 B / G1 B /
      Hygienic G1 B
    • Protection: IP65 up to IP68
  • Intrinsically safe level sensor GL- and Ex-approval *'*

    Typ: PT-HL | ID: UH

    technical features

    • Ranges: 0...0,1 bar up to 0...10 bar
    • Output: 4...20 mA
    • Voltage supply: Current loop, 16...30VDC
    • Accuracy: 0,5% (0,25%)of span
    • Protection: IP68
    • Material enclosure: CrNi-Stahl, Hastelloy
    • Temperature range: -10...+85 °C
    • Connection: Cable
  • Conductive Level Sensor

    Typ: PT-HL-T-C | ID: UQ

    technical features

    • Ranges: 0...0,1 bar up to 0...25 bar
    • Output: 4...20 mA
    • Accuracy: 20% of span (conductivity)
    • Temperature range: -10...+85 °C maximum with FEP-cable
    • Material casing: CrNi steel 316L
    • Electrical connection: Fixed cable, open end, 15 m (standard)
    • Protection: IP68
    • Pressure connection: CrNi: 1/2" B
    • Immersion depth: 300 m maximum with PUR-cable
  • Intrinsically safe level sensor | Ex-approval

    Typ: PT-IL | ID: UE

    technical features

    • Ranges: 0...0,1 bar up to 0...10 bar
    • Output: 4...20 mA
    • Accuracy: 0,5% of span (option: 0,25% of span)
    • Temperature range: -10...+85 °C
    • Material enclose: CrNi-Stahl (option: Hastelloy)
    • Electrical connection: cable
    • Protection: IP68
    • Pressure connection: CrNi: 1/2";       Hastelloy: 1/4" female
    • Immersion depth: 100 m maximum
  • Pressure transmitter for mobile hydraulic

    type: PT-MH | ID: UB

    technical features

    • Pressure: Relative
    • Ranges: 0...60 bar up to 0...600 bar
    • Output: 4...20 mA / 0...10 V / 1...5 V / 0,5...4,5 V
    • Accuracy: 1% of span / 2% of span
    • Temperature medium: -40...+125 °C
    • Material casing: plastic PTB
    • Pressure connection: G1/4A / M14x1,5 / 7/16-20UNF-2A / 1/4 NPT
    • Electrical connection: see technical data
    • Protection: at least IP67
  • Pressure transmitter SIL

    type: PT-SIL | ID: UI

    technical features


    • Ranges: 0...0,1 bar up to 0...1000 bar / -1...+24 bar
    • Output: Current / Voltage / Ratiometric
    • Supply: see data sheet
    • Accuracy: 0,5% (0,25%)of span
    • Degree of protection: IP67 (IP65 with valve plug)
    • Casing: 316Ti-steel
    • Process connection: G 1/2, G 1/4, 1/2 NPT, 1/4 NPT
    • Connection: See data sheet
  • Pressure transmitter standard

    type: PT-ST | ID: US

    technical features

    • Pressure: relative or absolute types
    • Ranges from 0...0,1 bar up to 0...1000 bar
    • Output: 0(4)...20 mA, 0...10 V, 0...5 V
    • Supply voltage: current loop, 10 (14)...30VDC
    • Accuracy: 0,5% (0,25%)of span
    • Degree of protection: IP65 or IP67
    • Medium contact parts and case of stainless steel (CrNi)
    • Process connection G 1/2, G 1/4, 1/2 NPT, 1/4 NPT
    • Connection: L-plug (valve), M12x1, cable
  • Pressure transmitter standard

    type: PT-ST2 | ID: UZ

    technical features

    • Pressure: Relative / Absolute / Vacuum & ±ranges
    • Ranges: 0...0,4 bar up to 0...1600 bar / -1...+59 bar
    • Output: Current / Voltage / Ratiometric
    • Supply: See data sheet
    • Accuracy: 0,5% (0,25%) of span
    • Degree of protection: IP67 (IP65 with valve plug)
    • Casing: 316Ti-steel
    • Process connection G 1/2, G 1/4, 1/2 NPT, 1/4 NPT
    • Connection: See data sheet