Signal transducer for potentiometer
type: SU-RX | ID: PU
technical features
- Input pot 0...400 Ohm up to 0...100 kOhm
- Analog output 4...20 mA (0...10 V)
- Supply 24 VDC +/-20%, 12 VDC, 115VAC, 230 VAC
- Zero drift below 0,2%/10K, gain drift below 0,1%/10K
- Easy mounting with top hat rail case
- Degree of protection IP20
- Adjustment of zero and gain
Limit value switch for standard signals
type: SU-LX | ID: NU
technical features
- Input 0...10 V, 0(4)...20 mA
- Relay with change-over contactt
- Indication of status of relay
- Switching when above or below limit value
- Supply 24 VDC +/-20%, optional 115/230 VAC
- Measuring fault less than 0,5% FS, temperature coefficient 50 ppm/K
- Easy mounting with top hat rail case
- Degree of protection IP20
- Adjustment of limit value and hysteresis
4-input summing amplifier
type: ASV | ID: SU
technical features
- 4 inputs 0(4)...20mA, 0...10V, selectable by DIP-switches
- Adding of input signals
- Output, 0(4)...20mA, 0...10 V, selectable by DIP-switches
- Accuracy +/- 0,1% of end of scale value
- Supply voltage 115/230VAC, optionally 24VAC/DC
- 2-wire transmitters can be supplied directly by the device
Digital video signal switch
Typ: DVU | ID: VU
technical features
- 4-channel video signal switch
- Channel selection "Auto" / "Manual" / "Digital"
- Switch-over time of the four channels in auto-mode adjustable
- BNC-jacks for inputs and output
- Supply: 115/230 VAC, 24 VAC/DC, galvanic separation
Process calibrator current voltage
type: PC-HA-VmA | ID: PK-0
technical features
- Output current: 20 mA
- Output voltage: 10 V
- Output: simulation transmitter
- Output: power supply current loop
- Resolution current: 0,001 mA
- Resolution voltage: 1 mV
- Accuracy current: 0,05% of set value/ 4 µA
- Accuracy voltage: 0,05% of set value / 2 mV
- Supply: 9 V battery
- Contained in delivery: transportation case, 1 set measuring cable