Configurator Modem Analog

Configurator Modem Analog

Type: DEV-KMA | ID: DK

Technical Features

  • PC interface: virtual serial port
  • Supply: out of USB connection
  • Current consumption: max. 350 mA
  • Connection transmitter: alligator clamps / M12, 4-pole
  • Connection PC: USB type A
  • Connection multimeter: bunch plugs
  • USB specification: 2.0 compatible
  • Protection: IP20
  • Case: ABS, 82x51x17 mm
  • Operating systems: Windows XP , Win 7, Win 8, Win 10
  • Software (included): TrComm

Analog Transmitter Universal OEM

Analog Transmitter Universal OEM

Type: MATU | ID: GD

Technical Features

  • Input: variable (programmable)
  • Output: 4…20 mA (2-wire / 3-wire)
  • Voltage output: 3-wire-only, multiple options
  • Digital I/Os: 3x
  • Measurement ranges: adjustable (programmable)
  • Resolution: 24 bit
  • Accuracy: max. 0,1% of nominal range
  • Operating temperature: -40…+85 °C
  • Connection: soldering pads
  • Dimensions: 35x18x4 mm / 31,4x28,6x4,8 mm
  • Supply: 9…35 VDC / 12…35 VDC (volt output)

2-Channel Transmitter IO-Link + PLc

2-Channel Transmitter IO-Link + PLc

Type: MEUTS-SIL | ID: IX

Technical Features

  • Input channel 1: Strain gauge full bridge
  • Input channel 2: Universal
  • Outputs: IO-Link interface and 4…20 mA
  • Supply: 24 VDC
  • Resolution: 16 bit / 24 bit
  • Response time PL c: max. 10 ms
  • Limit values: 2, with PL c, see page 4
  • Connection: Soldering pads
  • Protection class: IP00
  • Operating temperature: -20…+85 °C
  • Material: FR4, PBT

Data Logger DL-TagTemp-Stick

Data Logger DL-TagTemp-Stick

Type: DL-TagTemp-Stick

Technical Features

  • Sensor: Internal Temperature sensor
  • Measuring Range: -20°C to 70°C
  • Temperature Accuracy: ± 0.5°C to 25°C ± 1.0°C span
  • Resolution: 0.1°C
  • Memory Capacity: 32000 records
  • Acquisition Interval: Programmable 5 seconds to 18 hours
  • Interface: USB
  • Battery Runtime: 2 years (15 min interval)
  • Housing: Polyamide
  • Protection: IP 67

Data Logger DL-TagTemp-NFC

Data Logger DL-TagTemp-NFC

Type: DL-TagTemp-NFC

Technical Features

  • Sensor: External temperature sensor
  • Measuring Range: -40°C to 70°C
  • Temperature Accuracy: ± 0.5°C to 25°C ± 1.0°C span
  • Resulution: 0.1°C
  • Memory Capacity: 4020 records
  • Acquisition Interval: Programmable from 1 minute up to 4 hours
  • Interface: RFID ISO 15693/NFC-V
  • Battery Runtime: More than 1 year (30 min acquisition interval), non-replaceable
  • Housing: Polyamide
  • Protection: IP 68