Smart Probes - HVAC ultimate kit
Content:
2 x Clamp thermometer testo 115i
2 x High-pressure gauge testo 549i
2 x Thermohygrometer testo 605i
1 x Thermometer testo 905i
1 x Infrared thermometer testo 805i
1 x Thermal anemometer testo 405i
1 x Vane anemometer testo 410i
1 x Differential pressure measuring instrument testo 510i
1 x testo HVAC softcase
technical features
Smart Probes HVAC/R Ultimate kit:- For all measurements involving heating, air-conditioning, refrigeration and ventilation systems
- All Smart Probes for temperature, pressure, humidity and flow in one kit
- Display of measurement data progression as a graph or table
- Transmission and analysis of measurement data via testo Smart Probes App
Smart Probes - Mould kit
Content:
1 x Thermohygrometer testo 605i
1 x Infrared thermometer testo 805i
1 x testo Smart Case (Climate)
technical features
Smart Probes Mould kit:- Identify mould risk at an early stage using the testo Smart Probes App
- Measuring point marking with laser function
- Display and evaluation of the mould risk with the aid of traffic light colours
- Transmission and analysis of measurement data including photo documentation via testo Smart Probes App
- Measurement of air humidity and temperature in rooms and ducts
- Automatic calculation of the dew point and wet bulb temperature via testo Smart Probes App
- Non-contact infrared measurement of surface temperature
- Easy selection of emission level via stored materials list
Transmitter Temperature IO-Link
type: MCTT-E | ID: QA
technical features
- Input Pt100: 3-wire / -200...800 °C
- Input Type J: -210...1200 °C
- Input Type K: -200...1372 °C
- Input Type N: -200...1300 °C
- Accuracy: max. 0,05% of nominal range
- Operating temperature: -20...+80 °C
- Configuration: IO-Link interface
- Connection: Soldering pads
- Protection class: IP00
- Dimensions: 40 x 17 mm
- Casing: none
Transmitter temperature IO-Link
Type: TH-TIO | ID: TI
Technical Features
- Input RTD Pt100: 3-wire / -200...800 °C
- Input Type J: -210...1200 °C
- Input Type K: -200...1372 °C
- Input Type N: -200...1300 °C
- Accuracy: max. 0,02 % of nominal range
- Operating temperature: -20...+80 °C
- Configuration: IO-Link interface
- Connection: Terminal screws
- Protection: IP20
- Dimensions: Ø45x23 mm
- Casing: Synthetics PA66
Visualisization Software
type: MVS | ID: VS
technical features
- Function: Measured value visualization
Configuration of MVS-DR
Configuration of MVS-HD - Requirements: MacOS / Linux / Win7 - Win10
min. 100 MB HDD storage - Value indication: Table (with CSV-export)
Diagram
Live
Graphical (configurable)