Digital strain gauge and standard signal amplifier
type: ADLM-NS | ID: AD
technical features
- Input Strain gauge: up to 4 full bridges
- Input sensitivity: 0,1...5 mV/V
- Input standard signal: 4...20 mA, 0...10 V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: 24 VDC
- Resolution: 12 / 14 / 15 / 16 bit
- Combined error: 0,2% of end scale value
- Optionally: limit value switch / interface
- Degree of protection: IP20
- Adjustment: via RS232 interface
View the embedded image gallery online at:
https://mueller-ie.com/en/adlm-ns.html#sigProId220f9bc08c
https://mueller-ie.com/en/adlm-ns.html#sigProId220f9bc08c