Strain Gauge Transmitters
Strain Gauge Bridge Amplifier SIL1 + PL"c" + IO-Link
type: SMM-HD-SIL1 | ID: [?]
technical features
- […]
- Sensor input: 1x strain gauge full bridge (350 O)
- Strain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25...3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 9…35 VDC
- Accuracy: see technical data
- Protection class: IP65
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
- Approvals: SIL1 and Performance level c
Strain Gauge Bridge Amplifier SIL1 + PL"c"
type: SMM-DR-SIL1 | ID: RA
technical features
- Sensor input: 1x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25…3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 18…35VDC
- Accuracy: see technical data
- Protection: IP20
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Enclosure: DR22,5 (117,2x22,5x113,6)
- Certificate: SIL 1, Performance Level "c"
Strain Gauge Bridge Amplifier SIL1 + PL"c"
type: SMM-HD-SIL1 | ID: QX
technical features
- Sensor input: 1x strain gauge full bridge (350 O)
- Strain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25...3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 9…35 VDC
- Accuracy: see technical data
- Protection class: IP65
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Casing: U-CASE 2 (162,2 x 92,2 (101,1) x 60,2 mm)
- Approvals: SIL1 and Performance level c
Strain gauge amplifier IO-Link
Typ: MISG-IO | ID: FC
Technical features
- Input: 1 strain gauge full bridge
- Bridge load: minimal 350 Ohm
- Measurement range: free adjustable in a range of -32000...+32000
- Output: IO-Link
- Resolution: 16 bit
- Strain gauge supply: 3 VDC
- Gross error: 0,05% of range
- Electrical connection: several plugs, cable
- Casing: PBT GF30 black
- Dimensions: 72x28x35 mm (without electrical connection)
- Protection class: at least IP65
Strain gauge amplifier *'*
type: DRMU-S2 - DRSG-S2 | ID: DR series 2
technical features
- Input: 1 strain gauge full bridge
- Bridge resistance: 350 Ω minimum
- Output: 4...20 mA current loop
- Supply: Current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Strain gauge amplifier *'*
type: DRMU-S4 - DRSG-S4 | ID: DR series 4
technical features
- Input: 1 strain gauge full bridge
- Bridge resistance: 350 ohms minimun
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Digital Strain Gauge Amplifier *'*
type: ADHM-LC | ID: LH
technical features
- Connection: 1x strain gauge full bridge, 350 ohms
- Input sensitivity: 1...4 mV/V
- Configuration: via interface
- Output: 4...20 mA
- Supply: 12...40 VDC out of current loop
- Electrical connection: pluggable - Combined error: 0,3% of nominal range
- Resolution: 16 bit
- Enclosure: stainless steel
- Protection: IP 65
Strain Gauge Bridge Amplifier SIL3 + PL"e"
type: SMM-DR | ID: ▒
technical features
- Sensor input: 1x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Bridge supply: 5 VDC
- Analog output: 2x 4...20 mA
- Voltage supply: 24 VDC +/-10%
- Accuracy: 5% deviation channel A / channel B
- Protection: IP20
- Diagnostic input: Test pulse 24 VDC
- Enclosure: DR22,5 (117,2x22,5x113,6)
- Certificate: SIL 3, Performance Level "e"
Strain Gauge Bridge Amplifier SIL3 + PL"e"
type: SMM-HD | ID: ▒
technical features
- Sensor input: 1x or 2x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Bridge supply: 5 VDC
- Analog output: 2x 4...20 mA for each strain gauge
- Voltage supply: 24 VDC +/-10%
- Accuracy: 5% deviation channel A / channel B
- Protection: IP65
- Diagnostic input: Test pulse 24 VDC
- Enclosure: U-CASE2 (162,2 x 92,2 (101,1) x 60,2 mm)
- Certificate: SIL 3, Performance Level "e"
Digital strain gauge amplifier
type: ADLM-HD | ID: DD
technical features
- Input: up to 4 strain gauge full bridges
- Input sensitivity: 0,1...5 mV/V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: 24 VDC +/-30%
- Resolution: 12 / 14 / 15 / 16 bit
- Combined error: 0,2% of end scale value
- Optionally: limit value switch / interface / vibration protection
- Degree of protection: IP65
- Adjustment: via RS232 interface
Digital strain gauge and standard signal amplifier
type: ADLM-NS | ID: AD
technical features
- Input Strain gauge: up to 4 full bridges
- Input sensitivity: 0,1...5 mV/V
- Input standard signal: 4...20 mA, 0...10 V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: 24 VDC
- Resolution: 12 / 14 / 15 / 16 bit
- Combined error: 0,2% of end scale value
- Optionally: limit value switch / interface
- Degree of protection: IP20
- Adjustment: via RS232 interface
Digital strain gauge amplifier
type: DR-ADLM | ID: BD
technical features
- Input Strain gauge: up to 2 full bridges, 0(4)...20 mA, 0...10 V
- Input sensitivity: 0,1...5 mV/V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: 24 VDC
- Resolution: 12 / 14 / 15 / 16 bit
- Combined error: 0,2% of end scale value
- Optionally: interface
- Degree of protection: IP20
- Adjustment: via RS485 or USB interface
Strain gauge amplifier *'*
type: MISG | ID: MJ
technical features
- Input strain gauge: 1 full bridge, 4-wire
- Input sensitivity: 1...4 mV/V
- Output: 4...20 mA
- Voltage supply: 12...40 VDC
- Resolution: 16 bit
- Combined error: 0,3% of range
- Bridge supply: 1 VDC
- Protection: at least IP65
- Configuration: Software
Mobile digital strain gauge amplifier
type: ADLM-HA | ID: DM
technical features
- Input: 2 strain gauge full bridges
- Input sensitivity: 0,1...5 mV/V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: accumulator
- Resolution: 12 / 14 / 15 / 16 bit
- Combined error: 0,2% of end scale value
- Degree of protection: IP54
- Adjustment: via RS232 interface or programming keys
Digital load measuring system
type: DLM-HD | ID: LS
technical features
- TÜV approval for use in systems with AK4
- µP-device for simple programming
- 4 resistance strain gauge full-bridge sensors
- 2 adjustable limit switches, relay output with restraint
- Configurable analog output, 0...1(10)v or 0(4)...20mA galvanic insulation
- Interfaces RS232, RS485, Interbus S, LWL, CANbus, Profibus galvanically insulated
- Tare - function
- Redundant construction for limit switch and test equipment, monitoring of sensor break and short circuit
- Accuracy +/- 0,1% of end scale value
Digital measuring amplifier for strain gauge
type: SU-DX | ID: DL
technical features
- Input sensivity 01 to 5 mV/V
- Programmable via RS232 interface
- Analog output 4...20 mA and 0...10 V
- Supply voltage 24 VDC +/- 30%
- Combined error 0,2% FS
- Resolution 12 / 14 / 15 / 16 bit
- Enclosure plastics
- Degree of protection IP 67
Sixfold strain gauge summing-up box
type: DSV-6N | ID: SD
technical features
- Input: 6 strain gauge full bridges
- Output: 1 strain gauge summing-up signal
- Sensors: 4- or 6-wires
- Bridge supply: out of amplifier or internally
- Supply: 12...30 VDC VDC (optionally)
- Cascade circuit possible
- Connection: screwed pin and socket, lockable
- Cable entries: 7 pcs M16x1,5
Measuring amplifier strain gauge
type: ALM-HD2 | ID: AJ
technical features
- Input sensitivity (0,1 mV/V up to 4 mV/V) selectable by DIP-switches
- Connection of max. 4 resistance strain gauge sensors (full bridge, 350 ohms)
- Change over analog output 0 (4)...+/- 20 mA or 0 (2)...+/-10 V
- Sensor supply voltage internally continiously adjustable (4...14 V)
- 2 adjustable limit value switches (potential free change over contacts)
- Accuracy +/-0,1% of end of scale value
- Supply voltage 85...265 VAC or 24 VDC
Analog Strain Gauge Amplifier
type: ALM-NS | ID: AN
technical features
- Input strain gauge: up to 4 full bridges (350 Ω)
- Sensitivity strain gauge: 0,1...4 mV/V (by steps)
- Output: 2...10 V and 4...20 mA, 0...10 V and 0...20 mA
- Voltage supply: 42 VAC / 115 VAC / 230 VAC / 24 VAC24 VDC
galvanically isolated - Limit value: 2 floating contacts (option)
- Bridge supply: 4...14 V adjustable
- Linearity: ± 0,02% of terminal value
- Mounting: top hat rail
- Measurement monitoring: sensor break
- Adjustment limit value: no need to connect strain gauge
Digital measuring amplifier for strain gauge
type: ADLM-LC | ID: LA
technical features
- Input sensivity 01 to 5 mV/V
- Programmable via RS232 interface
- Analog output 4...20 mA and 0...10 V
- Supply voltage 24 VDC +/- 30%
- Combined error 0,2% FS
- Resolution 12 / 14 / 15 / 16 bit
- Enclosure stainless steel
- Degree of protection IP 65
Summing amplifier for resistance strain gauge
type: DSV | ID: DV
technical features
- 4 inputs resistance strain gauge, full bridges
- Addition of single measure values
- 1 output for connection to every measuring amplifier with input for resistance strain gauge bridges
- Cascading of several summing amplifiers is possible
- External power supply for the bridges can be connected on demand