DR-Series
Strain Gauge Bridge Amplifier SIL1 + PL"c"
type: SMM-DR-SIL1 | ID: RA
technical features
- Sensor input: 1x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Sensor supply: 1,25…3 VDC
- Analog output: 4…20 mA / 0…10 V / 0,5…10,5 V / 2…10 V
- Voltage supply: 18…35VDC
- Accuracy: see technical data
- Protection: IP20
- Vibration resistance: none
- Switch output: max. 30 VAC / VDC, at max. 500 mA
- Enclosure: DR22,5 (117,2x22,5x113,6)
- Certificate: SIL 1, Performance Level "c"
Converter for potentiometer *'*
type: DRMU-S2 - DRPO-S2 | ID: DR series 2
technical features
- Input: 3,3 kΩ
- Measuring current: 0,15 mA
- Output: 4...20 mA current loop
- Supply: Current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Converter for resistance *'*
type: DRMU-S2 - DRWI-S2 | ID: DR series 2
technical features
- Input: 3,3 kΩ
- Measuring current: 0,15 mA
- Output: 4...20 mA current loop
- Supply: Current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Standard signal transmitter 0...10 V *'*
type: DRMU-S2 - DRVO-S2 | ID: DR series 2
technical features
- Input: 0...10 V
- Input resistance: 20 kΩ
- Output: 4...20 mA current loop
- Supply: Current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Standard signal transmitter 0…20 mA *'*
type: DRMU-S2 - DRCU-S2 | ID: DR series 2
technical features
- Input: 0…20 mA
- Input resistance: 27 Ω
- Output: 4…20 mA current loop
- Supply: Current loop
- Electrical connection: 2…6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
RTD Pt 100 amplifier *'*
type: DRMU-S2 - DRRT-S2 | ID: DR series 2
technical features
- Input: 1 RTD Pt100 (2-,3-,4-wire)
- Output: 4...20 mA current loop
- Supply: Current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Converter for potentiometer *'*
type: DRMU-S4 - DRPO-S4 | ID: DR series 4
technical features
- Input: 3,3 kΩ
- Measuring current: 0,15 mA
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Converter for resistance *'*
type: DRMU-S4 - DRWI-S4 | ID: DR series 4
technical features
- Input: 3,3 kΩ
- Measuring current: 0,15 mA
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Standard signal transmitter 0...10 V *'*
type: DRMU-S4 - DRVO-S4 | ID: DR series 4
technical features
- Input: 0...10 V
- Input resistance: 20 kΩ
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Standard signal transmitter 0...20 mA *'*
type: DRMU-S4 - DRCU-S4 | ID: DR series 4
technical features
- Input: 0...20 mA
- Input resistance: 27 Ω
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
RTD Pt100 amplifier *'*
type: DRMU-S4 - DRRT-S4 | ID: DR series 4
technical features
- Input: 1 RTD Pt100 (2-,3-,4-wire)
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Universal transmitter
Type: MH-1U | ID: ▒
technical features
- measuring input: direct voltage, direct current, Pt100(0), thermocouple, frequency,
rotational speed, counter - display: red display of -199…999 digits
- digit height approx. 7mm
- min/max value recording
- 9 adjustable supporting points
- display flashing at threshold value exceedance / threshold value undercut
- Tara function
- programming interlock via access code
- pluggable screw-terminal
- optional: analog output 0-10 VDC, 0/4-20 mA switchable
- optional: interfaces RS232 / RS485 / Bluetooth
- optional: sensor supply incl. digital input
- optional: 2 relay outputs / 2 PhotoMos-outputs / 2 relay outputs & 2 PhotoMos-outputs
- optional: Bluetooth interface
- optional: data logger
- accessories: PC-based configuration kit PM-TOOL with CD & USB adapter
Transmitter standard signal for DIN rail
type: SP-DR | ID: ▒
technical features
- Input current: 0...20 mA - Input Voltage: 0...20 V
- Input resistance; 0...4000 ohms
- Output: 4...20 mA, galvanical insulation
- Supply: 6...32 VDC out of current loop
- Transmission error: 0,1% FS
- Configuration: RFID-Programmer
- Connection: Terminal screws
- Protection: IP20
- Dimensions: 18xs90x64 mm
- Enclosure: Synthetics black
Strain gauge amplifier *'*
type: DRMU-S2 - DRSG-S2 | ID: DR series 2
technical features
- Input: 1 strain gauge full bridge
- Bridge resistance: 350 Ω minimum
- Output: 4...20 mA current loop
- Supply: Current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: without
- Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Strain gauge amplifier *'*
type: DRMU-S4 - DRSG-S4 | ID: DR series 4
technical features
- Input: 1 strain gauge full bridge
- Bridge resistance: 350 ohms minimun
- Output: 4...20 mA current loop
- Supply: 24 VDC, 85...250 VAC, current loop
- Electrical connection: 2...6 plug-in terminal strip
- Limit vale contacts: 2x electronically,
2x relays - Protection: IP20
- Accuracy: see data sheet
- Enclosure: for DIN rail
Analog Summing Amplifier 4-Channel
type: DR-AS4K | ID: ▒
technical features
- Function: Arithmetic mean of input signals
- Input: 2...4x 4...20 mA
- Output: 1x 4...20 mA
- Supply: 24 VDC
- Current consumption: ca. 50 mA (without input signals)
- Connection: 4 plug-in terminal stips, 4-pole
- Temperature range: -10...60 °C (ambient)
- Protection: IP20
- Enclosure: DR22,5 made of PA66 GF30
Strain Gauge Bridge Amplifier SIL3 + PL"e"
type: SMM-DR | ID: ▒
technical features
- Sensor input: 1x strain gauge full bridge (350 ohms)
- Stain gauge sensitivity: up to 4 mV/V
- Bridge supply: 5 VDC
- Analog output: 2x 4...20 mA
- Voltage supply: 24 VDC +/-10%
- Accuracy: 5% deviation channel A / channel B
- Protection: IP20
- Diagnostic input: Test pulse 24 VDC
- Enclosure: DR22,5 (117,2x22,5x113,6)
- Certificate: SIL 3, Performance Level "e"
Digital strain gauge amplifier
type: DR-ADLM | ID: BD
technical features
- Input Strain gauge: up to 2 full bridges, 0(4)...20 mA, 0...10 V
- Input sensitivity: 0,1...5 mV/V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: 24 VDC
- Resolution: 12 / 14 / 15 / 16 bit
- Combined error: 0,2% of end scale value
- Optionally: interface
- Degree of protection: IP20
- Adjustment: via RS485 or USB interface
Double RTD transmitter
type: DRMU-W | ID: BW
technical features
- Input: 2x RTD Pt100, 3-wire
- Output: 2x 4...20 mA (Current loop)
- Voltage supply: 2x 10...35 VDC
- Mounting: on top hat rail
- Temperature ranges: within -50...+400 °C
- Accuracy: at least 0,5% of range
- Protection: IP20
- Enclosure: DR22,5 made of plastic PA66 GF30
- Connection: plug-in terminal strips
Analog Strain Gauge Amplifier
type: ALM-NS | ID: AN
technical features
- Input strain gauge: up to 4 full bridges (350 Ω)
- Sensitivity strain gauge: 0,1...4 mV/V (by steps)
- Output: 2...10 V and 4...20 mA, 0...10 V and 0...20 mA
- Voltage supply: 42 VAC / 115 VAC / 230 VAC / 24 VAC24 VDC
galvanically isolated - Limit value: 2 floating contacts (option)
- Bridge supply: 4...14 V adjustable
- Linearity: ± 0,02% of terminal value
- Mounting: top hat rail
- Measurement monitoring: sensor break
- Adjustment limit value: no need to connect strain gauge