Relative Pressure Transmitter *'*

type: MIPS | ID: MO

technical features

  • Input: pressure 0...10 mbar bis 0...100 mbar
  • Output: 4...20 mA current loop (2-wire)
  • Voltage supply: out of current loop (12...40 VDC)
  • Accuracy: see technical details
  • Process connection: 1x hose connection
  • Medium: clean dry air, dry gases
  • Electrical connection: several plugs / cable
  • Temperature range: -20...+80 °C (operation)
  • Adjustment: software
  • Material enclosure: PBT GF 30
  • Protection: at least IP65